Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2026 Mar:229:112427.
doi: 10.1016/j.apradiso.2026.112427. Epub 2026 Jan 14.

Sensitivity gains and quality control in radioxenon monitoring via laboratory Re-measurements

Affiliations
Free article

Sensitivity gains and quality control in radioxenon monitoring via laboratory Re-measurements

Mattias Aldener et al. Appl Radiat Isot. 2026 Mar.
Free article

Abstract

As a part of the Comprehensive Nuclear Test Ban Treaty (CTBT) the International Monitoring System (IMS), to monitor the compliance of member states to CTBT, is currently being established. The IMS consists of different monitoring techniques, of which the sampling and detection of radioactive noble gases, mainly radioxenon, is one. As a complement to the monitoring stations, a number of radionuclide laboratories are included in the IMS. Samples collected at a station can be sent to a laboratory for further analysis. However, due to the short half-lives of radioxenon isotopes, the benefits of conducting re-measurements in the laboratory are unclear, as the isotope may decay significantly during transport. The FOI facilities in Sweden host a SAUNA III IMS system and a radioxenon laboratory. The laboratory is equipped with a SAUNA Laboratory system for re-analysis of xenon samples collected using the IMS systems. To investigate both the advantages and limitations of laboratory re-measurements, several radioxenon samples from the IMS station are re-measured at the laboratory system, and compared to the SAUNA III results. This work shows that, in addition to ensuring quality control of the sampling and xenon purification process, laboratory re-measurements also provide a better detectability for most of the radioxenon isotopes. For 133Xe and 131mXe the detectability at the laboratory is as good as at the IMS station up to at least a week after the collection period, and can be improved further by increasing the measurement time at the laboratory. The higher sensitivity at the laboratory measurements also results in a better estimation of the isotopic ratios, which is important for classification of the detection.

PubMed Disclaimer

Conflict of interest statement

Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.

LinkOut - more resources