. 1974 Nov;28(5):822-30.
doi: 10.1128/am.28.5.822-830.1974.

Factors that influence microbial contamination of fluids associated with hemodialysis machines

Factors that influence microbial contamination of fluids associated with hemodialysis machines

M S Favero et al. Appl Microbiol. 1974 Nov.

Abstract

Studies were conducted on the microbiological quality of fluids associated with different types of dialysis systems located in six dialysis centers and 14 homes. Included were (i) single-pass systems employing either parallel flow (Kiil or Gambro) or capillary cartridge dialyzers and (ii) recirculating single-pass and batch recirculating systems using coil dialyzers. Microbiological assays were performed on the water used to prepare dialysis fluid, the concentrated dialysate, and either pre- and postdialyzer dialysate (single-pass systems) or the dialysate contained in storage reservoirs and recirculating cannisters (recirculating systems). The levels of microbial contamination consisting of gram-negative bacteria were directly related to the type of dialysis system, method of water treatment, distribution system, and in some instances, the type of dialyzer. Recirculating single-pass and batch recirculating systems consistently contained significantly higher levels of contamination than single-pass systems. These results were directly related to the design of recirculating systems which permits carbon- and nitrogen-containing waste products dialyzed from the patient to accumulate, be used as nutrients by microorganisms, and subsequently allow for 2- to 4-log increases in contamination levels during a dialysis treatment. In contrast, levels of contamination in single-pass machines were related more to the quality of the water used to prepare dialysis fluid and the adequacy of cleaning and disinfection procedures than to the design of the system.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Health Lab Sci. 1966 Jan;3(1):10-9 - PubMed
    1. Br Med J. 1964 Apr 4;1(5387):880-2 - PubMed
    1. Bacteriol Rev. 1969 Mar;33(1):1-47 - PubMed
    1. Isr J Med Sci. 1969 Sep-Oct;5(5):1032-6 - PubMed
    1. Appl Microbiol. 1969 Sep;18(3):376-86 - PubMed

MeSH terms

LinkOut - more resources