. 1979 Jan;32(1):56-60.
doi: 10.1136/jcp.32.1.56.

Interpretation of serum total calcium: effects of adjustment for albumin concentration on frequency of abnormal values and on detection of change in the individual

Interpretation of serum total calcium: effects of adjustment for albumin concentration on frequency of abnormal values and on detection of change in the individual

R B Payne et al. J Clin Pathol. 1979 Jan.

Abstract

Serum total calcium was measured in 1693 patients during a four-month period. We examined the effects of adjustment for albumin concentration on the interpretation of single measurements of serum total calcium and on the variation of series of measurements in individual patients. Markedly abnormal total calcium concentrations--2.75 mmol/l (11.0 mg/100 ml) or more, or 2.00 mmol/l (8.0 mg/100 ml) or less--were found in 115 patients, but only 24 (21%) remained markedly abnormal after adjustment for albumin. Three patients, two with malignant disease and one with primary hyperparathyroidism, had significant hypercalcaemia which was masked by hypoalbuminaemia. The serum total calcium measured on a subsequent occasion had changed 0.15 mmol/l (0.6 mg/100 ml) or more in 60 patients, but after adjustment for albumin this number was reduced to 27 (45%). The within-person standard deviation for serum total calcium was calculated in 26 patients with normal mean adjusted calcium concentrations who had had six or more sequential measurements. The mean standard deviation was 0.148 mmol/1 (0.59 mg/100 ml) and, after adjustment for albumin, this was reduced to 0.100 mmol/1 (0.40 mg/100 ml). We conclude that adjustment of serum total calcium concentration for albumin is essential to detect abnormal values and to assess changes in a value.