Monitoring ventricular function at rest and during exercise with a nonimaging nuclear detector
- PMID: 433780
- DOI: 10.1016/0002-9149(79)90362-x
Monitoring ventricular function at rest and during exercise with a nonimaging nuclear detector
Abstract
A portable nonimaging device, the nuclear stethoscope, for measuring beat to beat ventricular time-activity curves in normal people and patients with heart disease, both at rest and during exercise, is being developed and evaluated. The latest device has several operating modes that facilitate left ventricular and background localization, measurement of transit times and automatic calculation and display of left ventricular ejection fraction. The correlation coefficient of left ventricular ejection fraction obtained with the device and with a camera-computer system was 0.92 in 35 subjects. During bicycle exercise the ejection fraction in 15 normal persons increased from 44 to 64 percent (P less than 0.001), whereas among 12 patients with heart disease it was unchanged in 5 and decreased in 7.
Similar articles
-
Assessment of left ventricular function in coronary artery disease with the nuclear probe during intervention studies.Br Heart J. 1984 Oct;52(4):422-30. doi: 10.1136/hrt.52.4.422. Br Heart J. 1984. PMID: 6433946 Free PMC article.
-
The nuclear stethoscope in the cardiac care unit.Postgrad Med J. 1983;59 Suppl 3:112-4. Postgrad Med J. 1983. PMID: 6647197
-
Scintillation probe detector in the assessment of cardiovascular disease.Med Instrum. 1979 May-Jun;13(3):152-5. Med Instrum. 1979. PMID: 440174
-
A simple and rapid non-invasive radioisotope method to determine ventricular ejection fractions and cardiopulmonary transit times.Nuklearmedizin. 1977 Apr;16(2):57-62. Nuklearmedizin. 1977. PMID: 876842
-
[Aging of heart function in man].Presse Med. 1992 Jul 22;21(26):1216-21. Presse Med. 1992. PMID: 1329078 Review. French.
Cited by
-
Monitoring effects of alpha-human atrial natriuretic polypeptide (alpha-hANP) on left ventricular function in patients with essential hypertension with a cardiac probe.Eur J Nucl Med. 1987;13(7):335-7. doi: 10.1007/BF00252990. Eur J Nucl Med. 1987. PMID: 2962872
-
Effects of anesthetic induction on myocardial function and metabolism: a comparison of fentanyl, sufentanil and alfentanil.Can J Anaesth. 1988 May;35(3 ( Pt 1)):219-33. doi: 10.1007/BF03010615. Can J Anaesth. 1988. PMID: 2968185 Clinical Trial.
-
Measurements of the effects of percutaneous nitroglycerin on left ventricular performance in patients with coronary artery disease with a cardiac probe.Eur J Nucl Med. 1988;14(7-8):374-7. doi: 10.1007/BF00254387. Eur J Nucl Med. 1988. PMID: 3141188 Clinical Trial.
-
Factors influencing R wave amplitude in patients with ischaemic heart disease.Br Heart J. 1983 Jan;49(1):8-14. doi: 10.1136/hrt.49.1.8. Br Heart J. 1983. PMID: 6821614 Free PMC article.
-
Measurement of effects of the Chinese herbal medicine higenamine on left ventricular function using a cardiac probe.Eur J Nucl Med. 1983;8(6):233-6. doi: 10.1007/BF00522511. Eur J Nucl Med. 1983. PMID: 6873101
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources