Cooling towers and evaporative condensers
Abstract
By 31 October 1978 there had been four confirmed instances where the Legionnaires' disease bacterium had been isolated from water samples taken from cooling towers or evaporative condensers located near the site of an epidemic of Legionnaires' disease. These devices are widely used to reject unwanted heat into the atmosphere and vary greatly in size and configuration. However, the operation of all towers and condensers depends on intimate contact between the circulating water and ambient air. Airborne contaminants in the vicinity of these devices are likely to be absorbed to some degree by the circulating water. The airstream leaving a cooling tower is saturated with water vapor and may also contain a relatively minute portion of the circulating water in the form of fine droplets known as drift. It is common practice to bleed a small portion of the circulating water, including all contaminants, from the tower into a storm sewer, sanitary sewer, or even a nearby body of water.
Similar articles
-
Role of air sampling in investigation of an outbreak of legionnaires' disease associated with exposure to aerosols from an evaporative condenser.J Infect Dis. 1990 Jun;161(6):1257-61. doi: 10.1093/infdis/161.6.1257. J Infect Dis. 1990. PMID: 2345305
-
Nonpneumonic, short-incubation-period Legionellosis (Pontiac fever) in men who cleaned a steam turbine condenser.Science. 1979 Aug 17;205(4407):690-1. doi: 10.1126/science.462175. Science. 1979. PMID: 462175
-
Proximity of the home to a cooling tower and risk of non-outbreak Legionnaires' disease.BMJ. 1991 Feb 16;302(6773):378-83. doi: 10.1136/bmj.302.6773.378. BMJ. 1991. PMID: 2004142 Free PMC article.
-
[Incidence and significance of Legionella in industrial air conditioning systems].Schriftenr Ver Wasser Boden Lufthyg. 1993;91:231-40. Schriftenr Ver Wasser Boden Lufthyg. 1993. PMID: 8235479 Review. German. No abstract available.
-
Mode of transmission of Legionella pneumophila. A critical review.Arch Intern Med. 1986 Aug;146(8):1607-12. Arch Intern Med. 1986. PMID: 3524495 Review. No abstract available.
Cited by
-
Bacterial fouling of a hospital closed-loop cooling system by Pseudomonas sp.J Clin Microbiol. 1981 Jun;13(6):1060-5. doi: 10.1128/jcm.13.6.1060-1065.1981. J Clin Microbiol. 1981. PMID: 7251827 Free PMC article.
-
An alkaline approach to treating cooling towers for control of Legionella pneumophila.Appl Environ Microbiol. 1987 Aug;53(8):1775-9. doi: 10.1128/aem.53.8.1775-1779.1987. Appl Environ Microbiol. 1987. PMID: 3662515 Free PMC article.
-
Prevalence of anti-Legionella pneumophila antibodies in various groups with different risk factors in Seville (Spain).Eur J Epidemiol. 1987 Dec;3(4):436-8. doi: 10.1007/BF00145658. Eur J Epidemiol. 1987. PMID: 3319673
-
Failure of Legionella pneumophila sensitivities to predict culture results from disinfectant-treated air-conditioning cooling towers.Appl Environ Microbiol. 1982 Jan;43(1):240-4. doi: 10.1128/aem.43.1.240-244.1982. Appl Environ Microbiol. 1982. PMID: 7055374 Free PMC article.
-
Preliminary report on the pathogenicity of Legionella pneumophila for freshwater and soil amoebae.J Clin Pathol. 1980 Dec;33(12):1179-83. doi: 10.1136/jcp.33.12.1179. J Clin Pathol. 1980. PMID: 7451664 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources