Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1974 Mar;27(3):506-12.
doi: 10.1128/am.27.3.506-512.1974.

Recovery of poliovirus from turbid estuarine water on microporous filters by the use of celite

Recovery of poliovirus from turbid estuarine water on microporous filters by the use of celite

W F Hill Jr et al. Appl Microbiol. 1974 Mar.

Abstract

The application of a new step for recovering poliovirus from moderately to highly turbid estuarine water by the filter virus-adsorption technique was investigated. The experiments were conducted under both (i) laboratory-based conditions (200-ml volumes) where the turbidity was controlled and (ii) simulated field conditions (15- to 100-gal volumes) where the turbidity varied depending upon the hydrology of the raw estuarine water. The new step consisted of adding Celite to the turbid water prior to sampling for virus. In the experiments, the pH of the water was first adjusted to 3.5 and then AlCl(3) was added to 0.0005 M. Celite was added to a concentration of 0.01% and mixed thoroughly. Either an HE Cox M-780 microfilter (Cox Instrument, Div. of Lynch Corp., Detroit, Mich.) or an MF-membrane filter (Millipore Corp., Bedford, Mass.) was used as the virus adsorbent. Virus was eluted from the Celite-filter complex in situ at pH 9 with 5x nutrient broth. In the laboratory-based experiments, when turbidity ranged from 5.0 to 30.0 Jackson turbidity units (JTU), virus recovery ranged from 66 to 89%. In the simulated field experiments, when the turbidity ranged from 8.5 to 80.0 JTU, virus recovery ranged from <1 to 74%, depending upon the multiplicity of virus input and the level of turbidity. The new step greatly improved the filtration-flux of turbid water and significantly reduced the premature clogging problem usually observed with microporous filters.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Appl Microbiol. 1967 Jan;15(1):208 - PubMed
    1. Appl Microbiol. 1969 Jan;17(1):1-6 - PubMed
    1. Can J Microbiol. 1969 May;15(5):399-403 - PubMed
    1. J Virol. 1968 Jan;2(1):21-5 - PubMed
    1. Appl Microbiol. 1971 Mar;21(3):405-10 - PubMed

LinkOut - more resources