Comparison of passive haemagglutination and haemagglutination-inhibition techniques for detection of antibodies to rubella virus
- PMID: 438343
- PMCID: PMC1145596
- DOI: 10.1136/jcp.32.2.128
Comparison of passive haemagglutination and haemagglutination-inhibition techniques for detection of antibodies to rubella virus
Abstract
Because of the technical problems and length of time involved in the satisfactory performance of the haemagglutination-inhibition test for detection of rubella-specific antibodies, a commercially available passive haemagglutination (PHA) kit utilising rubella antigen-sensitised human erythrocytes was tested for its suitability for use in diagnostic laboratories. The immune response to acute rubella infections as measured by PHA was considerably delayed compared to the response measured by haemagglutination-inhitition. Titres of rubella-specific antibody only became comparable six months after the infection. The commercially available PHA kits is a useful addition to diagnostic laboratories for the determination of immune status and, in conjunction with the haemagglutination-inhibition test, can be an indicator of recent rubella infection.
Similar articles
-
New passive hemagglutination assay kit that uses hemagglutinin-sensitized erythrocytes for detection of rubella antibodies.J Clin Microbiol. 1982 Dec;16(6):1117-22. doi: 10.1128/jcm.16.6.1117-1122.1982. J Clin Microbiol. 1982. PMID: 7161376 Free PMC article.
-
Screening for rubella antibodies by a single radial haemolysis test.NIPH Ann. 1979 Dec;2(2):25-30. NIPH Ann. 1979. PMID: 398458
-
Further evaluation of a rubella passive hemagglutination test.J Med Virol. 1980;5(2):131-6. doi: 10.1002/jmv.1890050206. J Med Virol. 1980. PMID: 7373286
-
A rubella haemagglutination inhibitor simulating antibody.Acta Pathol Microbiol Scand B Microbiol Immunol. 1973 Dec;81(6):719-23. doi: 10.1111/j.1699-0463.1973.tb02266.x. Acta Pathol Microbiol Scand B Microbiol Immunol. 1973. PMID: 4521970 No abstract available.
-
Laboratory diagnosis of rubella virus infections.Can Med Assoc J. 1973 Apr 7;108(7):894-5 passim. Can Med Assoc J. 1973. PMID: 4581796 Free PMC article. Review. No abstract available.
Cited by
-
Collection tubes with or without gel separator did not interfere with detection of rubella virus antibodies IgM and IgG.J Clin Lab Anal. 2007;21(5):330-4. doi: 10.1002/jcla.20194. J Clin Lab Anal. 2007. PMID: 17847106 Free PMC article.
-
Differences in antibody responses with rapid agglutination tests for the detection of rubella antibodies.J Clin Microbiol. 1986 Apr;23(4):772-6. doi: 10.1128/jcm.23.4.772-776.1986. J Clin Microbiol. 1986. PMID: 3517065 Free PMC article.
-
Assay of rubella antibody by passive hemagglutination and by a modified indirect immunofluorescence test.Infection. 1980;8 Suppl 3:S 255-60. doi: 10.1007/BF01639591. Infection. 1980. PMID: 6997203
-
Diagnosis of postnatally acquired rubella by use of three enzyme-linked immunosorbent assays for specific immunoglobulins G and M and single radial hemolysis for specific immunoglobulin G.J Clin Microbiol. 1984 Nov;20(5):951-8. doi: 10.1128/jcm.20.5.951-958.1984. J Clin Microbiol. 1984. PMID: 6392326 Free PMC article.
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources