Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1974 Nov;242(3):729-58.
doi: 10.1113/jphysiol.1974.sp010732.

Changes in time scale and sensitivity in turtle photoreceptors

Changes in time scale and sensitivity in turtle photoreceptors

D A Baylor et al. J Physiol. 1974 Nov.

Abstract

1. In turtle cones the steady-state relation between the internal potential and log light intensity was much flatter in the steady state than it was at 30 msec after the beginning of a step of light; this is attributed to a desensitization which develops with a delay of 50-100 msec.2. When a weak flash was superposed on a steady background light which hyperpolarized the cone by 3-6 mV the amplitude of the linear response to a flash was reduced to 1/e and the time to maximum was shortened from about 110 to 70 msec; the response also became diphasic. With stronger background lights the flash sensitivity continued to fall, but the time to maximum did not become shorter than 40-50 msec and lengthened again with very strong lights.3. In cones the flash sensitivity S(F) was reduced to half its dark value S(F) (D) by a light intensity of 1/S(F) (D)zeta where zeta is about 20 sec/V.4. At low levels of background light, about two-thirds of the change in sensitivity was time-dependent and one-third was attributable to the ;instantaneous non-linearity' described in the previous paper.5. The reduction in time to peak and the decrease in sensitivity produced by a background light which hyperpolarized by about 3 mV was little affected by changing the diameter of the area illuminated from 12 to 800 mum.6. An experiment with a rod showed that a very weak light which hyperpolarized by only 0.5 mV decreased the linear response to 1/e and shortened the time to maximum from 300 to 180 msec.7. With weak or moderate flashes the time-dependent desensitization lagged behind the potential by 50-100 msec.8. The desensitization and shortening of time scale which persisted after a flash or step were associated with an after-hyperpolarization. The relaxation of potential, sensitivity and time scale became slower as the preceding illumination was increased from 10(3) to 10(10) photons mum(-2); the increase seemed to occur in steps involving components which relaxed with time constants of the order of 0.1, 1, 10 and 100 sec. A rebound phenomenon was observed after steps longer than 30 sec and with equivalent intensities greater than 10(5) photons mum(-2) sec(-1).9. Several of the observations are explained by a hypothesis in which the central assumption is that the particles which block the ionic channels are degraded or removed by an autocatalytic reaction.

PubMed Disclaimer

References

    1. J Physiol. 1965 Jan;176:38-45 - PubMed
    1. Proc R Soc Lond B Biol Sci. 1965 Mar 16;162:20-46 - PubMed
    1. J Physiol. 1970 Mar;207(1):77-92 - PubMed
    1. J Physiol. 1973 Oct;234(1):163-98 - PubMed
    1. J Physiol. 1974 Nov;242(3):685-727 - PubMed

Publication types

LinkOut - more resources