Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1979 Apr 12;41(1):1-15.
doi: 10.1007/BF00424464.

Frequency and amplitude analysis of the EMG during exercise on the bicycle ergometer

Frequency and amplitude analysis of the EMG during exercise on the bicycle ergometer

J S Petrofsky. Eur J Appl Physiol Occup Physiol. .

Abstract

The surface EMG was recorded from above the quadriceps muscle in 3 male subjects during bicycle ergometry at work loads between 20 and 100% of the VO2 max to measure the EMG amplitude (RMS) and frequency (assessed from the center frequency of the power spectra) during this type of work. During brief (3 min) bouts of work the RMS amplitude of the EMG was linearly related to the work load; the center frequency of the EMG power spectra was the same at all work loads examined. In contrast, during sustained bouts of work maintained for 80 min at 20 and 40% of the VO2 max, the RMS amplitude of the EMG remained constant while the center frequency initially increased for the first 20 min of work and then progressively decreased as the work continued. When work loads of 60, 80, and 100% of the VO2 max were sustained to fatigue, the RMS amplitude continually increased while the EMG frequency decreased from the beginning to the end of the work periods. The results of this study showed that the EMG is a complex waveform, being influenced not only by fatigue, but to even a larger extent in many cases, the temperature of the exercising muscles. Therefore, although muscular fatigue caused an increase in the RMS amplitude and decrease in the center frequency, the increase in muscle temperature associated with the work opposed these changes by causing a reduction in the RMS amplitude and an increase in the center frequency.

PubMed Disclaimer

References

    1. Am J Physiol. 1970 Nov;219(5):1324-9 - PubMed
    1. Am J Phys Med. 1968 Jun;47(3):125-35 - PubMed
    1. J Appl Physiol. 1975 Feb;38(2):208-11 - PubMed
    1. Am J Phys Med. 1963 Oct;42:192-204 - PubMed
    1. Eur J Appl Physiol Occup Physiol. 1976 Mar 9;35(1):1-10 - PubMed

Publication types