Particle counting immunoassay (PACIA). III. Automated determination of circulating immune complexes by inhibition of an agglutinating factor of mouse serum
- PMID: 469265
- DOI: 10.1016/0022-1759(79)90323-5
Particle counting immunoassay (PACIA). III. Automated determination of circulating immune complexes by inhibition of an agglutinating factor of mouse serum
Abstract
A factor capable of agglutinating human IgG coated particles (latex) has been found in mouse serum. This factor (MAG) was used in an unpurified form to detect circulating immune complexes in the particle counting immunoassay (PACIA) system, which allows measurement of agglutination with great precision. MAG did not react with monomeric IgG, nor with reduced and alkylated aggregated IgG. It was inhibited by immune complexes in small antigen excess. Among the various subclasses of IgG, IgA and IgM, only IgG1 and IgM when coupled to Sepharose beads displayed an inhibitory activity towards MAG. That the inhibitory factors detected in serum were immune complexes or aggregated Ig was suggested by the correlation obtained with the amounts of 'heavy' IgG found in the serum samples by Ultrogel chromatography and by the polydisperse distribution of the inhibitory factors in the heavy fraction of gradient ultracentrifugation.
Similar articles
-
Particle counting immunoassay (PACIA). II. Automated determination of circulating immune complexes by inhibition of the agglutinating activity of rheumatoid sera.J Immunol Methods. 1978;23(1-2):29-50. doi: 10.1016/0022-1759(78)90107-2. J Immunol Methods. 1978. PMID: 308973
-
Particle counting immunoassay (PACIA) of ferritin.J Clin Chem Clin Biochem. 1982 Mar;20(3):141-6. doi: 10.1515/cclm.1982.20.3.141. J Clin Chem Clin Biochem. 1982. PMID: 7077228
-
Detection of circulating antigen-antibody complexes by their inhibitory effect on the agglutination of IgG-coated particles by rheumatioid factor of Clq.Clin Exp Immunol. 1976 Aug;25(2):212-26. Clin Exp Immunol. 1976. PMID: 954232 Free PMC article.
-
Typing of subclasses and light chains of human monoclonal immunoglobulins by particle counting immunoassay (PACIA).J Immunol Methods. 1984 Apr 27;69(2):229-41. doi: 10.1016/0022-1759(84)90321-1. J Immunol Methods. 1984. PMID: 6425415
-
Particle counting immunoassay. IV. The use of F(ab')2 fragments and N epsilon-chloroacetyl lysine N-carboxyanhydride for their coupling to polystyrene latex particles.J Immunol Methods. 1979;28(1-2):25-32. doi: 10.1016/0022-1759(79)90324-7. J Immunol Methods. 1979. PMID: 469268
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Research Materials
Miscellaneous