Ultrasonic identification of sources of gaseous microemboli during open heart surgery
- PMID: 4724497
- PMCID: PMC470033
- DOI: 10.1136/thx.28.3.295
Ultrasonic identification of sources of gaseous microemboli during open heart surgery
Abstract
An ultrasonic transducer was used to detect gaseous microemboli during open heart surgery. When placed over the carotid artery of patients during surgery it was recognized that gaseous emboli were released into the systemic circulation following recognizable surgical procedures and from the oxygenator during bypass. Fixation of the transducer on the arterial return from the oxygenator demonstrated that the two types of disposable bubble oxygenators and disc oxygenators tested delivered microbubbles in the arterial blood. Some factors affecting the number of bubbles released were recognized and are discussed. Case reports of two patients who received large volumes of gaseous microemboli from different sources are presented.
Similar articles
-
The production of microemboli by various blood oxygenators.Ann Thorac Surg. 1970 Mar;9(3):221-8. doi: 10.1016/s0003-4975(10)65494-x. Ann Thorac Surg. 1970. PMID: 5413746 No abstract available.
-
[Gas embolism in operations with artificial circulation].Grudn Khir. 1988 Jan-Feb;(1):32-6. Grudn Khir. 1988. PMID: 3280418 Russian. No abstract available.
-
Microgasemboli in a pump oxygenator during open-heart surgery.Arch Chir Neerl. 1974;26(1):41-53. Arch Chir Neerl. 1974. PMID: 4842319 No abstract available.
-
Mechanical cardiopulmonary substitution during open heart surgery.Cardiovasc Clin. 1971;3(3):134-52. Cardiovasc Clin. 1971. PMID: 4946019 Review. No abstract available.
-
Impact of oxygenator characteristics on its capability to remove gaseous microemboli.J Extra Corpor Technol. 2007 Dec;39(4):271-3. J Extra Corpor Technol. 2007. PMID: 18293817 Review.
Cited by
-
An ultrasonic analysis of the comparative efficiency of various cardiotomy reservoirs and micropore blood filters.Thorax. 1978 Jun;33(3):352-8. doi: 10.1136/thx.33.3.352. Thorax. 1978. PMID: 684672 Free PMC article.
-
A novel software program for detection of potential air emboli during cardiac surgery.Cardiovasc Ultrasound. 2015 Jan 12;13:3. doi: 10.1186/1476-7120-13-3. Cardiovasc Ultrasound. 2015. PMID: 25582221 Free PMC article.
-
Detection of bubbles in blood vessels and extracorporeal circuits.Med Biol Eng Comput. 1979 Jul;17(4):534-5. doi: 10.1007/BF02447069. Med Biol Eng Comput. 1979. PMID: 316064 No abstract available.
-
Ultrasonic diagnosis in pediatrics. The state of the art of ultrasonic diagnosis in pediatrics today. Part II.Pediatr Radiol. 1976 Apr 14;4(3):175-85. doi: 10.1007/BF00975353. Pediatr Radiol. 1976. PMID: 787907 Review. No abstract available.
-
Cerebral protection during open-heart surgery.Thorax. 1977 Oct;32(5):525-33. doi: 10.1136/thx.32.5.525. Thorax. 1977. PMID: 594930 Free PMC article.
References
MeSH terms
LinkOut - more resources
Full Text Sources