[Combined use of computerized tomography and echography in ophthalmology (author's transl)]
- PMID: 480834
[Combined use of computerized tomography and echography in ophthalmology (author's transl)]
Abstract
Computerized tomography does not give as fine an information as echography in the presence of intraocular changes, such as retinal detachments, organized vitreous hemorrhages or the differentiation of a choroidal prominence. Complementary computerized tomography, however, can be helpful in the presence of unclear echographic results in opaque media. Furthermore, an analysis of the value of computerized tomography and echography for the evaluation of orbital lesions is presented based mainly on the results of the preoperative tissue diagnosis in 31 histological proven lesions. The results show that a complementary CT-scan is not necessary in orbital lesions of the anterior third when a clear echographic tissue diagnosis exists. In lesions of the middle third of the orbit, echography and CT complement each other. For lesions situated within the orbital apex or for those which are in connection with adjacent structures, such as the intracranial space or the periorbital region, computerized tomography is superior and of a greater help than standardized A-scan echography aided by contact B-scan.
Similar articles
-
[Combined A- and B-scan echography of the eye (author's transl)].Klin Monbl Augenheilkd. 1977 Jan;170(1):24-32. Klin Monbl Augenheilkd. 1977. PMID: 850352 German.
-
Ocular and orbital echography.Radiol Clin North Am. 1975 Dec;13(3):523-41. Radiol Clin North Am. 1975. PMID: 812142 Review.
-
[Value of ultrasonic echography in ophthalmology].J Radiol Electrol Med Nucl. 1972 Oct;53(10):711-5. J Radiol Electrol Med Nucl. 1972. PMID: 4640536 French. No abstract available.
-
Standardized echography. Part I: A-Scan examination procedures.Int Ophthalmol Clin. 1979 Winter;19(4):267-81. Int Ophthalmol Clin. 1979. PMID: 536133 No abstract available.
-
Standardized echography: basic principles, clinical applications, and results.Int Ophthalmol Clin. 1979 Winter;19(4):127-210. Int Ophthalmol Clin. 1979. PMID: 395120 Review. No abstract available.
Cited by
-
CT of malignant choroidal melanoma - morphology and perfusion characteristics.Neuroradiology. 1982;23(1):23-30. doi: 10.1007/BF00399701. Neuroradiology. 1982. PMID: 7070660
-
Sonography and computed tomography in the diagnosis of orbitocranial malformations and tumors.Neurosurg Rev. 1987;10(2):93-101. doi: 10.1007/BF01741444. Neurosurg Rev. 1987. PMID: 3329303
-
CT of the orbit: current status with high resolution computed tomography.Neuroradiology. 1983;24(4):183-92. doi: 10.1007/BF00399769. Neuroradiology. 1983. PMID: 6828234 No abstract available.
Publication types
MeSH terms
LinkOut - more resources
Miscellaneous