Occupational asthma in an electronics factory: a case control study to evaluate aetiological factors
- PMID: 483204
- PMCID: PMC471064
- DOI: 10.1136/thx.34.3.300
Occupational asthma in an electronics factory: a case control study to evaluate aetiological factors
Abstract
This is the final part of a study carried out to investigate occupational asthma due to sensitivity to colophony fumes (a component of soldering flux) in an electronics factory. Fifty-eight workers with occupational asthma employed on the main shop floor were investigated. In them the interval between first exposure and sensitisation varied widely with a group becoming sensitive within one to two years of first exposure, and another group whose sensitisation was delayed for three to 23 years. Once sensitised the interval between arriving at work and the onset of daily symptoms seemed to be bimodally distributed, resembling the immediate and late asthmatic symptoms seen on provocation testing. Twenty-three out of 58 had no definite daily deterioration at work but improved at the weekends. Wheeze and breathlessness occurred in the evenings at home in most, and one-third were woken by breathlessness at least on some nights. These 58 cases were compared with 48 controls without occupational asthma who had worked on the same shop floor for at least four years. Mean levels of FEV1 were significantly worse in the cases before exposure on Monday morning. The cases also had more than twice as much sickness absence as controls. FEV1 fell by more than 10% over a working shift in 33% of cases and 5% of controls. Atopy (a positive skin prick test to one or more common allergens) and a past history of allergic disease were weakly but significantly associated with being a case. The effects of smoking and a family history of allergic disease were trivial. Prick testing with an antigen derived from the colophony in the solder flux was completely negative, but cases and controls had significantly raised levels of total IgM compared with blood bank controls, perhaps suggesting some previously unrecognised immunological process.
Similar articles
-
Occupational asthma in an electronics factory.Thorax. 1979 Feb;34(1):13-8. doi: 10.1136/thx.34.1.13. Thorax. 1979. PMID: 441994 Free PMC article.
-
[Occupational asthma due to colophony].Med Lav. 1985 Sep-Oct;76(5):371-8. Med Lav. 1985. PMID: 4088120 Italian. No abstract available.
-
Work-related respiratory disease in employees leaving an electronics factory.Thorax. 1979 Feb;34(1):19-22. doi: 10.1136/thx.34.1.19. Thorax. 1979. PMID: 441996 Free PMC article.
-
Mechanisms of occupational asthma induced by isocyanates.Ann Occup Hyg. 1998 Jan;42(1):33-6. doi: 10.1016/s0003-4878(97)00047-1. Ann Occup Hyg. 1998. PMID: 9566113 Review.
-
[Occupational asthma from the use of synthetic resins. Personal case histories and a review of the literature].Minerva Med. 1986 Oct 13;77(39):1807-12. Minerva Med. 1986. PMID: 3534630 Review. Italian.
Cited by
-
Occupational asthma.J R Soc Med. 1982 Apr;75(4):225-6. doi: 10.1177/014107688207500401. J R Soc Med. 1982. PMID: 7069690 Free PMC article. No abstract available.
-
Occupational asthma due to unheated colophony.Br J Ind Med. 1986 Aug;43(8):559-60. doi: 10.1136/oem.43.8.559. Br J Ind Med. 1986. PMID: 3730307 Free PMC article. No abstract available.
-
Occupational asthma in a factory making flux-cored solder containing colophony.Thorax. 1981 Nov;36(11):828-34. doi: 10.1136/thx.36.11.828. Thorax. 1981. PMID: 7330804 Free PMC article.
-
Rubber glove asthma.Br Med J (Clin Res Ed). 1988 Feb 20;296(6621):531-2. doi: 10.1136/bmj.296.6621.531-a. Br Med J (Clin Res Ed). 1988. PMID: 3126894 Free PMC article. No abstract available.
-
Compensating occupational asthma.Thorax. 1981 Dec;36(12):881-4. doi: 10.1136/thx.36.12.881. Thorax. 1981. PMID: 6461087 Free PMC article. Review. No abstract available.
References
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Miscellaneous