Peak flow rate records in the diagnosis of occupational asthma due to colophony
- PMID: 483205
- PMCID: PMC471066
- DOI: 10.1136/thx.34.3.308
Peak flow rate records in the diagnosis of occupational asthma due to colophony
Abstract
Peak expiratory flow rate (PEFR) has been measured hourly from waking to sleeping in 29 workers with respiratory symptoms exposed to the fumes of soft soldering fluxes containing colophony (pine resin). Thirty-nine records of mean length 33 days have been analysed, and the results compared with the occupational history and bronchial provocation testing in the same workers. From plots of daily mean, maximum, and minimum PEFR, recurring physiological patterns of asthma emerge. The most common pattern is for asthma to increase with each successive working day. Some workers have an equivalent deterioration each working day. Regular recovery patterns taking one, two, and three days are described. The combination of a three-day recovery pattern and a late asthmatic reaction on Monday results in Monday being the best day of each week. Assessment of these records has shown them to be specific and sensitive, provided the worker was not taking corticosteroids or sodium cromoglycate during the period of the record and that bronchodilator usage was kept constant on days at home and at work. The results of the PEFR records correlate well with bronchial provocation testing, and provide a suitable alternative to this for the diagnosis of mild to moderate occupational asthma. The records are of particular use for screening symptomatic workers whose symptoms appear unlikely to be related to work.
Similar articles
-
Peak flow rate records in the diagnosis of occupational asthma due to isocyanates.Thorax. 1979 Jun;34(3):317-23. doi: 10.1136/thx.34.3.317. Thorax. 1979. PMID: 225841 Free PMC article.
-
Occupational asthma in electronics workers caused by colophony fumes: follow-up of affected workers.Thorax. 1982 May;37(5):348-53. doi: 10.1136/thx.37.5.348. Thorax. 1982. PMID: 7112471 Free PMC article.
-
Bronchial provocation studies in workers exposed to the fumes of electronic soldering fluxes.Clin Allergy. 1980 Mar;10(2):137-49. doi: 10.1111/j.1365-2222.1980.tb02091.x. Clin Allergy. 1980. PMID: 7389068
-
Adverse effects of colophony.Ind Health. 1997;35(1):1-7. doi: 10.2486/indhealth.35.1. Ind Health. 1997. PMID: 9009495 Review.
-
Use of pulmonary function tests in the diagnosis of occupational asthma.Ann Allergy Asthma Immunol. 2003 May;90(5 Suppl 2):47-51. doi: 10.1016/s1081-1206(10)61649-3. Ann Allergy Asthma Immunol. 2003. PMID: 12772952 Review.
Cited by
-
Peak flow rate records in surveys: reproducibility of observers' reports.Thorax. 1984 Nov;39(11):828-32. doi: 10.1136/thx.39.11.828. Thorax. 1984. PMID: 6505990 Free PMC article.
-
Serial measurements of peak expiratory flow and responsiveness to methacholine in the diagnosis of aluminium potroom asthma.Thorax. 1992 Apr;47(4):292-7. doi: 10.1136/thx.47.4.292. Thorax. 1992. PMID: 1585295 Free PMC article.
-
Occupational asthma.J R Soc Med. 1982 Apr;75(4):225-6. doi: 10.1177/014107688207500401. J R Soc Med. 1982. PMID: 7069690 Free PMC article. No abstract available.
-
The epidemiological importance of intraindividual changes in objective pulmonary responses.Eur J Epidemiol. 1987 Dec;3(4):390-8. doi: 10.1007/BF00145651. Eur J Epidemiol. 1987. PMID: 3319671 Review.
-
Occupational asthma.West J Med. 1982 Dec;137(6):480-5. West J Med. 1982. PMID: 7164429 Free PMC article.
References
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources