Reduction of nitrous oxide contamination in a paediatric hospital
- PMID: 487231
- DOI: 10.1007/BF03006450
Reduction of nitrous oxide contamination in a paediatric hospital
Abstract
Ambient nitrous oxide concentrations were recorded in an operating room during delivery of the gas at low and medium flow-rates, with and without the application of simple scavenging devices. Residual background levels of nitrous oxide were still present more than one hour after disconnection of the flowmeters and use of the room. Scavenging reduced concentrations ten-fold. Adjacent corridors and the post-anaesthetic recovery room were contaminated with nitrous oxide from the operating rooms and from patients. A vigorous programme of checking for leaks and repairing and maintaining equipment, coupled with the use of suction scavenging, can reduce atmospheric contamination with nitrous oxide below 30 p.p.m., which is well within the limit suggested by the U.S. National Institute for Occupational Safety and Health.
Similar articles
-
Occupational exposure to anaesthetics in 20 hospitals.Anaesthesia. 1980 Apr;35(4):354-9. doi: 10.1111/j.1365-2044.1980.tb05116.x. Anaesthesia. 1980. PMID: 7435894
-
A study of waste gas scavenging in operating theatres.Anaesth Intensive Care. 1978 Aug;6(3):215-21. doi: 10.1177/0310057X7800600307. Anaesth Intensive Care. 1978. PMID: 281160
-
Blood concentrations of nitrous oxide in theatre personnel.Br J Anaesth. 1980 Nov;52(11):1143-8. doi: 10.1093/bja/52.11.1143. Br J Anaesth. 1980. PMID: 7426220
-
[Pollution of surgical suites by anesthetic gases. Anti-pollution devices].Cah Anesthesiol. 1985 Mar;33(2):153-8. Cah Anesthesiol. 1985. PMID: 3888355 Review. French. No abstract available.
-
[Survey of anesthetic pollution in the operating room].Masui. 1977 Apr;26(4):369-86. Masui. 1977. PMID: 325241 Review. Japanese. No abstract available.
Cited by
-