Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1969 Apr;17(4):568-76.
doi: 10.1128/am.17.4.568-576.1969.

Isolation of anaerobic bacteria from human gingiva and mouse cecum by means of a simplified glove box procedure

Isolation of anaerobic bacteria from human gingiva and mouse cecum by means of a simplified glove box procedure

A Arank et al. Appl Microbiol. 1969 Apr.

Abstract

An anaerobic glove box constructed of clear flexible vinyl plastic is described. It is sufficiently inexpensive and simple in operation to be used not only in research but also in a clinical laboratory by technicians without special training. Conventional bacteriological techniques may be used inside the glove box for culturing and transferring anaerobic bacteria. The box may be heated to 37 C and thus serve as an anaerobic incubator as well, permitting inspection of cultures at any time. Media may be prepared and agar plates may be poured on the laboratory bench in the conventional manner. An overlay of trace amounts of palladium black catalyst over plated agar media reduces the medium to an oxidation-reduction (O-R) potential of - 300 mv within 2 days after introduction into the glove box. In spite of its greater simplicity, the system matched or excelled the roll tube method with respect to all parameters tested, including O-R potential obtainable in the media, O(2) concentration in the gas phase, and efficiency in isolating anaerobic bacteria from the mouse cecum. Comparative studies indicate that the conventional anaerobic jar method was inadequate for the isolation of strict anaerobes from human gingival specimens and from the mouse cecum. This was due to the exposure of specimens and media to air during plating on the open laboratory bench. Anaerobic jars were adequate for maintaining the proper conditions for growth of anaerobic bacteria once these had been established in the glove box.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Antonie Van Leeuwenhoek. 1966;32(2):212-22 - PubMed
    1. Proc Soc Exp Biol Med. 1967 Mar;124(3):903-9 - PubMed
    1. J Pathol Bacteriol. 1967 Oct;94(2):417-27 - PubMed
    1. J Exp Med. 1968 Jul 1;128(1):97-110 - PubMed
    1. Can J Microbiol. 1954 Aug;1(1):55-64 - PubMed

LinkOut - more resources