Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1975 Aug;46(2):279-86.

Basophil counting with a new staining method using alcian blue

  • PMID: 49201
Free article
Comparative Study

Basophil counting with a new staining method using alcian blue

H S Gilbert et al. Blood. 1975 Aug.
Free article

Abstract

Difficulties in obtaining reproducible and accurate enumeration of circulating basophils with existing techniques have hampered investigation of this infrequent cell population. A new basophil staining method is described that employs alcian blue dye for staining of heparin within basophils at low pH and in the presence of lanthanum ions. Basophil recognition is facilitated by reducing nonspecific nuclear staining. This objective is achieved because of the differences in stability of alcian blue-heparin, alcian blue-nucleic acid, lanthanum-heparin, and lanthanum-mucliec acid complexes. Reduction of pH after staining also favors solubilization of leukocyte cytoplasmic proteins, providing greater contrast between stained and unstained cells by reducing light scattering of the unstained leukocytes . The alcian blue staining method is suitable both for chamber basophil counting and automated basophil counting using continuous-flow sampling and electro-optical detection. The new staining method was evaluated by comparing it with the chamber counting method using toluidine blue in a triple-blind study in which the results of basophil counting by the alcian blue chamber method, alcian blue automated instrument method, and the toluidine blue chamber method were analyzed for reproducibility and compared with an indirect basophil count obtained from a 1000-cell leukocyte differential and a total leukocyte count. Both alcian blue staining methods gave greater reporducibility that toluidine blue and were more accurate, as evidinced by a significantly higher correlation with the indirect basophil count. The improved reproducibility, accuracy, and convenience of this method over existing methods should facilitate the collection of more meaningful information about circulating basophil levels in health and disease.

PubMed Disclaimer

Publication types

LinkOut - more resources