[Are automatic devices suitable for blood pressure determinations?]
- PMID: 493912
[Are automatic devices suitable for blood pressure determinations?]
Abstract
Four automatic blood pressure recorders (Bosograph II, Bosch EBM 500, Elag BE 237R, and Physiometrics SR-2) were compared with the random zero sphygmomanometer. Since each of the automatic devices was calibrated for phase IV, diastolic blood pressure values were read off at phase IV and not phase V of Korotkow with the random zero sphygmomanometer. Blood pressure measurements were carried out in 80 patients with hypertension and in 20 normotensive healthy subjects. Readings with the automatic recorders and with the random zero sphygmomanometer correlated well in a wide range of systolic and diastolic blood pressure (r = 0.878--0.982, p less than 0.001). However, the automatic values were in most cases significantly lower than those obtained with the random zero device. For Physiometrics SR-2, where two diastolic readings were possible, only the first diastolic values correlated well with phase IV of Korotkow. The second values were significantly lower, with a difference of -11.1 mm Hg, and probably did not reflect the true diastolic blood pressure. These results show that each of the four automatic recorders is suitable for measuring blood pressure. However, with the Physiometrics SR-2, Only the higher diastolic reading should be used. The differences between the four automatic devices were minor and can therefore be ignored.
Similar articles
-
Random zero sphygmomanometer versus automatic oscillometric blood pressure monitor; is either the instrument of choice?J Hum Hypertens. 1995 Nov;9(11):885-9. J Hum Hypertens. 1995. PMID: 8583467 Clinical Trial.
-
[Comparative study of 24-hour ambulatory blood pressure monitors with standard zero and random zero sphygmomanometers].Orv Hetil. 1994 Jun 26;135(26):1415-9. Orv Hetil. 1994. PMID: 8028897 Hungarian.
-
Validation of two automatic devices for self-measurement of blood pressure according to the International Protocol of the European Society of Hypertension: the Omron M6 (HEM-7001-E) and the Omron R7 (HEM 637-IT).Blood Press Monit. 2006 Jun;11(3):165-71. doi: 10.1097/01.mbp.0000209078.17246.34. Blood Press Monit. 2006. PMID: 16702826
-
Comparison of two automatic blood pressure recorders and the mercury sphygomomanometer.Hypertension. 1982 Mar-Apr;4(2):329-36. doi: 10.1161/01.hyp.4.2.329. Hypertension. 1982. PMID: 7068191
-
Validation of TONOPORT V blood-pressure measuring monitor in adults.J Hum Hypertens. 2005 Sep;19(9):745-9. doi: 10.1038/sj.jhh.1001876. J Hum Hypertens. 2005. PMID: 15951741
Cited by
-
Single cuff comparison of two methods for indirect measurement of arterial blood pressure: standard auscultatory method versus automatic oscillometric method.Basic Res Cardiol. 1986 Jan-Feb;81(1):101-9. doi: 10.1007/BF01907432. Basic Res Cardiol. 1986. PMID: 3718426
Publication types
MeSH terms
LinkOut - more resources
Research Materials