Vasomotor responses to the Valsalva manoeuvre in normal subjects and in patients with diabetes mellitus
- PMID: 508473
- PMCID: PMC482177
- DOI: 10.1136/hrt.42.4.422
Vasomotor responses to the Valsalva manoeuvre in normal subjects and in patients with diabetes mellitus
Abstract
Cardiovascular responses to the Valsalva manoeuvre were examined in 19 non-diabetic subjects and 32 diabetic patients, some with signs of autonomic dysfunction. All the non-diabetic subjects showed an overshoot in systemic arterial pressure and a bradycardia after the manoeuvre, and in 11 of them only forearm vasoconstriction occurred. However, in eight non-diabetic subjects a forearm vasodilatation was observed at some stage after the Valsalva manoeuvre. Similar patterns of vasomotor responses were seen in some of the diabetic patients. However, those diabetics with postural hypotension showed a systemic arterial hypotension after the Valsalva manoeuvre with no significant change in forearm vascular resistance. Such a response is abnormal but forearm vasodilatation alone may not be.
Similar articles
-
Non-invasive assessment of left ventricular response to Valsalva manoeuvre in normal and diabetic subjects using praecordial accelerocardiography.Br Heart J. 1979 Feb;41(2):199-203. doi: 10.1136/hrt.41.2.199. Br Heart J. 1979. PMID: 426965 Free PMC article.
-
Baroreflex sensitivity and responses to the Valsalva manoeuvre in subjects with diabetes mellitus.J Neurol Neurosurg Psychiatry. 1976 Feb;39(2):178-83. doi: 10.1136/jnnp.39.2.178. J Neurol Neurosurg Psychiatry. 1976. PMID: 1262893 Free PMC article.
-
Intraocular pressure responses to systemic autonomic stimulation in diabetes mellitus.Doc Ophthalmol. 1989 Jun;72(2):141-53. doi: 10.1007/BF00156704. Doc Ophthalmol. 1989. PMID: 2582995
-
[Blood pressure and heart rate regulation in diabetics].Arch Mal Coeur Vaiss. 2000 Dec;93 Spec No 4:51-8. Arch Mal Coeur Vaiss. 2000. PMID: 11296464 Review. French.
-
The Valsalva manoeuvre: physiology and clinical examples.Acta Physiol (Oxf). 2016 Jun;217(2):103-19. doi: 10.1111/apha.12639. Epub 2016 Jan 5. Acta Physiol (Oxf). 2016. PMID: 26662857 Review.
Cited by
-
Synchronized wearables for the detection of haemodynamic states via electrocardiography and multispectral photoplethysmography.Nat Biomed Eng. 2023 Oct;7(10):1229-1241. doi: 10.1038/s41551-023-01098-y. Epub 2023 Oct 2. Nat Biomed Eng. 2023. PMID: 37783757 Free PMC article.
-
Forearm vascular resistance responses to the Valsalva maneuver in healthy young and older adults.Clin Auton Res. 2021 Dec;31(6):737-753. doi: 10.1007/s10286-021-00810-9. Epub 2021 May 20. Clin Auton Res. 2021. PMID: 34014418
-
Assessment of autonomic disturbances in multiple sclerosis by measurement of heart rate responses to deep breathing and to standing.Ital J Neurol Sci. 1982 Jul;3(2):111-4. doi: 10.1007/BF02043941. Ital J Neurol Sci. 1982. PMID: 7118523 No abstract available.
References
MeSH terms
LinkOut - more resources
Full Text Sources