Cardiovascular signs of acute hypoxaemia and hypercarbia during enflurane and halothane anaesthesia in man
- PMID: 509344
- DOI: 10.1007/BF03006288
Cardiovascular signs of acute hypoxaemia and hypercarbia during enflurane and halothane anaesthesia in man
Abstract
We investigated the impact of enflurane and halothane (1.1 MAC) on heart rate and blood pressure responses to experimental hypoxaemia (PETo2 6.0 kPa [45 torr]) and small increments in PCO2 (1.3--1.6 KPa [10--12 torr]). The results reaffirm that circulatory signs of mild hypercarbia are vitually abolished by these anaesthetics. The important new observation is that signs of acute moderate hypoxaemia are also markedly depressed. Although potential modifying factors such as surgical stimulation were not evaluated, this study indicates that human subjects anaesthetized with enflurane or halothane lack reliable cardiovascular signs of acute hypoxaemia.
Similar articles
-
Surgical stimulation does not enhance ventilatory chemoreflexes during enflurane anaesthesia in man.Can Anaesth Soc J. 1980 Jan;27(1):22-8. doi: 10.1007/BF03006843. Can Anaesth Soc J. 1980. PMID: 7353187
-
Depression of hypoxic ventilatory response by halothane, enflurane and isoflurane in dogs.Br J Anaesth. 1977 Oct;49(10):957-63. doi: 10.1093/bja/49.10.957. Br J Anaesth. 1977. PMID: 921874
-
Doses of epinephrine causing arrhythmia during enflurane, methoxyflurane and halothane anaesthesia in dogs.Can Anaesth Soc J. 1975 Jul;22(4):495-501. doi: 10.1007/BF03004865. Can Anaesth Soc J. 1975. PMID: 237613
-
Inhalation anaesthetics and liver damage.S Afr Med J. 1993 Nov;Suppl:1-4. S Afr Med J. 1993. PMID: 7839181 Review. No abstract available.
-
[Inhalation anesthetics in patients with coronary heart disease: contra].Anasthesiol Intensivmed Notfallmed Schmerzther. 1993 Feb;28(1):52-5. Anasthesiol Intensivmed Notfallmed Schmerzther. 1993. PMID: 8467034 Review. German. No abstract available.
Cited by
-
Hypoxic gas mixtures delivered by anaesthetic machines equipped with a downstream oxygen flowmeter.Can Anaesth Soc J. 1980 Nov;27(6):527-30. doi: 10.1007/BF03006878. Can Anaesth Soc J. 1980. PMID: 6452939
-
Pulse oximetry: evaluation of accuracy during outpatient general anesthesia for oral surgery.Anesth Prog. 1988 Mar-Apr;35(2):53-60. Anesth Prog. 1988. PMID: 3166346 Free PMC article.
-
Variable effects of anaesthetics on the ventilatory response to hypoxaemia in man.Can Anaesth Soc J. 1982 Mar;29(2):93-9. doi: 10.1007/BF03007983. Can Anaesth Soc J. 1982. PMID: 6802469
-
Ventilation and chemoreflexes during enflurane sedation and anaesthesia in man.Can Anaesth Soc J. 1979 Sep;26(5):353-60. doi: 10.1007/BF03006447. Can Anaesth Soc J. 1979. PMID: 487229
-
Evaluation of arterial oxygenation during anaesthesia.Can Anaesth Soc J. 1985 May;32(3 Pt 2):S16-9. doi: 10.1007/BF03009439. Can Anaesth Soc J. 1985. PMID: 4005687