An evaluation of four methods for measuring cholesterol absorption by the intestine in man
- PMID: 5108132
An evaluation of four methods for measuring cholesterol absorption by the intestine in man
Abstract
Critical comparisons have been made in 12 patients of four methods for measuring cholesterol absorption from the intestine. Methods I-III depend on the use of labeled cholesterol (intravenously or continuous labeling orally) in conjunction with sterol balance measurements; Method IV can be carried out with only a single test dose containing labeled cholesterol plus labeled beta-sitosterol. In the latter technique absorption is calculated as the loss of cholesterol relative to beta-sitosterol during intestinal transit. Method III (isotopic steady-state method) proved to be undependable because of uncertainties in determining the existence of an isotopic steady state. However, Method IV gave good agreement with Methods I and II, and it appears to have certain practical as well as theoretical advantages. Although Method IV requires collections of stools for up to 8 days, it is nevertheless the most rapid and the simplest of all the methods for estimating absorption. It can also be used in certain situations, such as in fur-licking animals, when Methods I and II are inadequate. Therefore, this method would seem to be a valuable addition to other isotopic techniques for estimating cholesterol absorption in man.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources