Comparative Study
. 1979 Oct;18(4):177-80.

[Accuracy of liver scintigraphy in focal liver disease; a comparison with postmortem studies in 159 cases (author's transl)]

[Article in German]
  • PMID: 530844
Comparative Study

[Accuracy of liver scintigraphy in focal liver disease; a comparison with postmortem studies in 159 cases (author's transl)]

[Article in German]
H J Biersack et al. Nuklearmedizin. 1979 Oct.

Abstract

In recent literature numerous papers have been published concerning the accuracy of scintigraphic detection of liver metastases. Unfortunately however, the problem of false positive results is not particularly discussed in these papers. Because of the lack of information it was our aim to compare our own scintigraphic results with postmortem histopathological findings. Our investigations were carried out in 139 patients with various types of malignancy. Included in the investigations were 20 patients with primary liver tumor. The interval between scintigraphic examination and the histological verification ranged from 3 days to 1 year. In 62 of the patients with liver metastases, histopathology revealed liver metastases, while 77 patients showed no liver involvement. We arrived at the correct diagnosis "liver metastasis" in 50 out of 62 patients (80.6%). False negative scintigrams (19.4%) were found in most of the respective cases when diffuse malignant involvement such as leukemia and Hodgkin's disease was present, and also when the size of the metastases was less than 2 cm in diameter. Fifty six out of 77 patients (72.7%) without histopathological evidence of liver metastases revealed negative scintigrams. Twenty one (27.3%) false positive scintigrams were mostly due to (diffuse) nonmalignant disease e.g. fibrosis and cirrhosis. The overall accuracy of liver scintigraphy in our study was 76.2%. In 18 of 20 (90%) patients with focal liver disease correct diagnosis was established. 7 patients with benign liver tumors and 11 of 13 patients with hepatocellular carcinoma showed focal defects. Considering the fact that liver scintigraphy is a non-invasive procedure, it can be recommended as screening method. In connection with sonography and computer tomography liver scintigraphy can undoubtedly improve the diagnostic accuracy in detecting liver metastases and primary liver tumors.