Passive haemagglutination test for antibodies against rabies virus
- PMID: 5317009
- PMCID: PMC2427979
Passive haemagglutination test for antibodies against rabies virus
Abstract
All the procedures now available for the measurement of rabies virus antibodies in serum have certain disadvantages. The serum neutralization test (SN), whether carried out by assay in mice or by the plaque-reduction technique, requires several days before the titrations are completed, necessitates special facilities for keeping large numbers of animals and tissue-culture plates, and is relatively expensive. A complement-fixation test is very insensitive, giving low titres in comparison with SN tests, and a haemagglutination-inhibition procedure is complicated by the presence of nonspecific reactions. A rabies passive haemagglutination technique (RPHA), developed to overcome many of these problems, is described.Titres obtained with human sera by the RPHA procedure correlated well with those obtained by SN tests. Both IgG and IgM classes of antibodies were measured by the RPHA procedure; however, it appeared to be more sensitive for detecting IgM than was the SN test and, therefore, gave higher titres for this class of immunoglobulins.
Similar articles
-
[Rabies specific IgM- and IgG-antibody response in persons immunized with HDCS vaccine according to the Essen postexposure vaccination schedule (author's transl)].Zentralbl Bakteriol Orig A. 1979 Dec;245(4):429-41. Zentralbl Bakteriol Orig A. 1979. PMID: 44937 Clinical Trial. German.
-
Further studies on an improved haemagglutination inhibition test with higher sensitivity for rabies virus antibody.Bull World Health Organ. 1986;64(1):133-7. Bull World Health Organ. 1986. PMID: 3488135 Free PMC article.
-
Methods of increasing the sensitivity of the haemagglutination inhibition test for rabies virus antibody.Bull World Health Organ. 1984;62(6):883-92. Bull World Health Organ. 1984. PMID: 6335846 Free PMC article.
-
Passive haemagglutination test for rabies antibodies.Monogr Ser World Health Organ. 1973;(23):147-50. Monogr Ser World Health Organ. 1973. PMID: 4219471 No abstract available.
-
The counterimmunoelectrophoresis test for detection of antibodies to rabies virus.Ann Microbiol (Paris). 1977 Apr;128A(3):331-7. Ann Microbiol (Paris). 1977. PMID: 921140
Cited by
-
A rapid reproducible test for determining rabies neutralizing antibody.Bull World Health Organ. 1973 May;48(5):535-41. Bull World Health Organ. 1973. PMID: 4544144 Free PMC article.
References
MeSH terms
Substances
LinkOut - more resources
Full Text Sources