The demonstration of alternating contractile state in pulsus alternans
- PMID: 5422019
- PMCID: PMC322583
- DOI: 10.1172/JCI106331
The demonstration of alternating contractile state in pulsus alternans
Abstract
Pulsus alternans was induced in 11 anesthetized, open-chest dogs by rapid atrial pacing, and the left ventricular filling characteristics and length-tension-velocity relationship of alternating beats were compared. The end-diastolic circumferences (cire) of the strong beats were slightly, but significantly, increased over the weak beats (7.3 > 6.9 cm, P < 0.01), confirming that diastolic filling does alternate in pulsus alternans. This alternation in initial fiber length seemed to result from an alternation in the prior end-systolic length, rather than from an alternation in diastolic filling time or compliance. There was also no difference in end-diastolic tension as measured by an isometric strain gauge suggesting no difference in contractile element relaxation before weak and strong beats. THE CONTRACTILE STATE OF THE STRONG BEATS WAS CONSISTENTLY GREATER THAN THAT OF THE WEAK BEATS WHEN CONTRACTILITY WAS DEFINED IN TERMS OF: (a) V(max) (3.13 > 2.53 circ/sec, P < 0.01); and (b) the velocity of circumferential fiber shortening (0.84 > 0.39 circ/sec, P < 0.001) and developed tension (82.5 > 74 g/cm, P < 0.01) at isolength. The length-tension-velocity relationship of the left ventricle also varied between strong and weak beats when: (a) the maximum velocity of contractile element shortening at least common tension (1.68 > 1.28 circ/sec, P < 0.05); and (b) the velocity of circumferential fiber shortening (0.81 > 0.39 circ/sec, P < 0.001) at maximum developed tension were examined. Analysis of the length-tension-velocity characteristics of sequential beats at the onset of alternans in three dogs suggests that an alternation in contractility initiates alternans, with secondary alternations in ventricular filling. Cross-clamping of the aorta in three other dogs essentially eliminated the alternating changes in end-diastolic length and pressure, while the resultant isovolumic contractions continued to demonstrate clear evidence of pulsus alternans in the ventricular systolic pressure, suggesting the persistance of an alternating contractile state. The evidence suggests that an important mechanism in the production and propagation of pulsus alternans, as produced in the intact canine ventricle by rapid pacing, is a beat-to-beat alternation in contractile state with secondary alternations in ventricular filling.
Similar articles
-
Alternating contractility in pulsus alternans studied in the isolated canine heart.Circulation. 1985 Feb;71(2):357-62. doi: 10.1161/01.cir.71.2.357. Circulation. 1985. PMID: 3965175
-
End-systolic pressure-diameter relationships during pulsus alternans in intact pig hearts.Am J Physiol. 1986 Apr;250(4 Pt 2):H606-11. doi: 10.1152/ajpheart.1986.250.4.H606. Am J Physiol. 1986. PMID: 3963216
-
Pulsus alternans induced by inferior vena caval occlusion in man.Cathet Cardiovasc Diagn. 1988;14(1):24-32. doi: 10.1002/ccd.1810140106. Cathet Cardiovasc Diagn. 1988. PMID: 3349514
-
Pulsus Alternans: Caught in Action.Catheter Cardiovasc Interv. 2025 Jan;105(1):270-271. doi: 10.1002/ccd.31295. Epub 2024 Nov 18. Catheter Cardiovasc Interv. 2025. PMID: 39558476 Review.
-
Right-sided pulsus alternans in diastolic left ventricular dysfunction.Catheter Cardiovasc Interv. 1999 Jul;47(3):336-9. doi: 10.1002/(sici)1522-726x(199907)47:3<336::aid-ccd20>3.0.co;2-#. Catheter Cardiovasc Interv. 1999. PMID: 10402293 Review.
Cited by
-
A TAT-frataxin fusion protein increases lifespan and cardiac function in a conditional Friedreich's ataxia mouse model.Hum Mol Genet. 2012 Mar 15;21(6):1230-47. doi: 10.1093/hmg/ddr554. Epub 2011 Nov 23. Hum Mol Genet. 2012. PMID: 22113996 Free PMC article.
-
2:1 Pulsus and electrical alternans during atrioventricular reciprocating tachycardia in a healthy young man: A case report.HeartRhythm Case Rep. 2021 Nov 9;8(2):89-92. doi: 10.1016/j.hrcr.2021.11.006. eCollection 2022 Feb. HeartRhythm Case Rep. 2021. PMID: 35242545 Free PMC article. No abstract available.
-
Alternating atrial electromechanical dissociation as contributing factor for pulsus alternans.Br Heart J. 1982 Nov;48(5):459-61. doi: 10.1136/hrt.48.5.459. Br Heart J. 1982. PMID: 7138709 Free PMC article.
-
Regional alternans in relaxation and the onset of pulsus alternans in the heart of the anaesthetized pig.J Physiol. 1994 Nov 15;481 ( Pt 1)(Pt 1):207-15. doi: 10.1113/jphysiol.1994.sp020431. J Physiol. 1994. PMID: 7853243 Free PMC article.
-
Pulsus alternans in regionally hypoxic ventricles of open-chest dogs: regional mechanical alternation of potentiation and attenuation of the inotropic state.Basic Res Cardiol. 1979 Nov-Dec;74(6):639-48. doi: 10.1007/BF01907505. Basic Res Cardiol. 1979. PMID: 94997
References
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Research Materials