. 1971 Feb;11(2):211-34.
doi: 10.1016/S0006-3495(71)86209-4.

Membrane current noise in lobster axon under voltage clamp

Membrane current noise in lobster axon under voltage clamp

D J Poussart. Biophys J. 1971 Feb.

Abstract

Random fluctuations in the steady-state current of neural membrane were measured in the giant lobster axon by means of a low noise voltage-clamp system. The power density spectrum S(f) of the fluctuations was evaluated between 20 and 5120 Hz and found to be of the type 1/f. Mean values of the potassium, sodium, and leakage currents I(K), I(Na), and I(L) were also measured by usual voltage-clamp techniques. Comparisons between these two types of data recorded under a number of different experimental conditions, such as presence of tetrodotoxin (TTX), substitution of calcium by lanthanum, and changes in the external concentration of potassium, have strongly suggested that the intensity of the fluctuations is related to the magnitude of I(K).

PubMed Disclaimer

References

    1. J Gen Physiol. 1966 Nov;50(2):461-71 - PubMed
    1. J Neurophysiol. 1965 Jul;28:742-72 - PubMed
    1. Ann N Y Acad Sci. 1966 Jul 14;137(2):818-29 - PubMed
    1. J Gen Physiol. 1968 May 1;51(5):1-7 - PubMed
    1. Nature. 1959 Jan 24;183(4656):265-6 - PubMed