Tumor detection by nuclear magnetic resonance
- PMID: 5544870
- DOI: 10.1126/science.171.3976.1151
Tumor detection by nuclear magnetic resonance
Abstract
Spin echo nuclear magnetic resonance measurements may be used as a method for discriminating between malignant tumors and normal tissue. Measurements of spin-lattice (T(1)) and spin-spin (T(2)) magnetic relaxation times were made in six normal tissues in the rat (muscle, kidney, stomach, intestine, brain, and liver) and in two malignant solid tumors, Walker sarcoma and Novikoff hepatoma. Relaxation times for the two malignant tumors were distinctly outside the range of values for the normal tissues studied, an indication that the malignant tissues were characterized by an increase in the motional freedom of tissue water molecules. The possibility of using magnetic relaxation methods for rapid discrimination between benign and malignant surgical specimens has also been considered. Spin-lattice relaxation times for two benign fibroadenomas were distinct from those for both malignant tissues and were the same as those of muscle.
Similar articles
-
Improved discrimination of normal and malignant tissue using 1H NMR relaxation time measurements at 2.18 MHz.Physiol Chem Phys Med NMR. 1984;16(1):49-55. Physiol Chem Phys Med NMR. 1984. PMID: 6541347
-
NMR in cancer: VIII. Phosphorus-31 as a nuclear probe for malignant tumors.Physiol Chem Phys. 1977;9(4-5):473-83. Physiol Chem Phys. 1977. PMID: 613335
-
Tissue water content and nuclear magnetic resonance in normal and tumor tissues.Cancer Res. 1975 May;35(5):1164-7. Cancer Res. 1975. PMID: 1120306
-
A review of 1H nuclear magnetic resonance relaxation in pathology: are T1 and T2 diagnostic?Med Phys. 1987 Jan-Feb;14(1):1-37. doi: 10.1118/1.596111. Med Phys. 1987. PMID: 3031439 Review.
-
Role of paramagnetic ions and water proton spin-lattice relaxation time in biological systems.Nuklearmedizin. 1993 Feb;32(1):52-6. Nuklearmedizin. 1993. PMID: 8385322 Review.
Cited by
-
Development of a Single-Sided Nuclear Magnetic Resonance Scanner for the In Vivo Quantification of Live Cattle Marbling.Appl Magn Reson. 2015;46(5):593-606. doi: 10.1007/s00723-015-0657-4. Epub 2015 Mar 18. Appl Magn Reson. 2015. PMID: 25937706 Free PMC article.
-
Advances in using MRI probes and sensors for in vivo cell tracking as applied to regenerative medicine.Dis Model Mech. 2015 Apr;8(4):323-36. doi: 10.1242/dmm.018499. Epub 2015 Apr 1. Dis Model Mech. 2015. PMID: 26035841 Free PMC article. Review.
-
Imaging in translational cancer research.Cancer Biol Med. 2022 Dec 5;19(11):1565-85. doi: 10.20892/j.issn.2095-3941.2022.0677. Cancer Biol Med. 2022. PMID: 36476372 Free PMC article. Review.
-
Advantages of paramagnetic chemical exchange saturation transfer (CEST) complexes having slow to intermediate water exchange properties as responsive MRI agents.NMR Biomed. 2013 Jul;26(7):829-38. doi: 10.1002/nbm.2874. Epub 2012 Oct 11. NMR Biomed. 2013. PMID: 23055299 Free PMC article. Review.
-
Proton T1 study of coverage parameter changes in tissues from tumor-bearing mice.Biophys J. 1979 Jan;25(1):203-8. doi: 10.1016/S0006-3495(79)85285-6. Biophys J. 1979. PMID: 233571 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources