Long-term experience with porcine aortic valve xenografts
- PMID: 556634
Long-term experience with porcine aortic valve xenografts
Abstract
Between 1971 and 1975, glutaraldehyde-preserved porcine aortic valve xenografts were employed for isolated replacement of the mitral valve (MVR) in 243 patients, replacement of the aortic valve (AVR) in 167 patients, and double valve replacement (AVR and MVR) in 51 patients. Postoperatively, long-term anticoagulation was not routinely given. Operative mortality rates for AVR, MVR, and double valve groups were 7.8, 6.0, and 11.8 per cent, respectively; the majority of early postoperative deaths were associated with concomitant coronary artery disease. No death was attributable to xenograft dysfunction. Follow-up of all patients was obtained. The total duration of follow-up for the MVR group was 347 patient-years, for the AVR GROUP 148 148 patient-years, and for double valve replacement 37 patient-years; maximum follow-up for these three groups was 4.4, 4.0, and 2.4 years, respectively. Actuarial analysis of postoperative survival rates at a common interval of 3 years showed 78 per cent for MVR patients, 91 per cent for AVR patients, and 80 per cent (projected) for patients with double valve replacement (85, 96, and 91 per cent for operative survivors, respectively. At this same interval 92 per cent of MVR patients, 99 per cent of AVR patients, and 93 per cent (projected) of patients with double valve replacement were free of thromboembolic episodes. Altogether, 12 of the total 512 valves implanted exhibited some evidence of dysfunction during the entire period of follow-up evaluation, but in only 2 instances (both mitral) was intrinsic pathological involvement of the xenograft tissue documented. Actuarial analysis of xenograft dysfunction at a common interval of 3 years after operation showed 95 per cent of MVR patients, 98 per cent of AVR patients, and 97 per cent (projected) of patients with double valve replacement to be free of this complication. These data support the use of glutaraldehyde-preserved porcine xenografts as superior bioprostheses that pose a low risk of thromboembolism without anticoagulation. The over-all durability of such valves, within the restriction of a maximum current follow-up interval of 4.4 years, appears comparable to that of currently available mechanical prostheses and justifies continued clinical use.
Similar articles
-
Twenty-year clinical experience with porcine bioprostheses.Ann Thorac Surg. 1996 Nov;62(5):1301-11; discussion 1311-2. doi: 10.1016/0003-4975(96)00629-7. Ann Thorac Surg. 1996. PMID: 8893561
-
Eighteen-year follow up after Hancock II bioprosthesis insertion.J Heart Valve Dis. 1999 Jan;8(1):16-24. J Heart Valve Dis. 1999. PMID: 10096477
-
Clinical evaluation of the carbomedics prosthesis: experience at providence health system in Portland.J Heart Valve Dis. 2002 Nov;11(6):844-50. J Heart Valve Dis. 2002. PMID: 12479287 Clinical Trial.
-
Seventeen-year experience with the St. Jude medical biocor porcine bioprosthesis.J Heart Valve Dis. 2005 Jul;14(4):486-92. J Heart Valve Dis. 2005. PMID: 16116875
-
Five-year evaluation of the Carpentier-Edwards porcine bioprosthesis.J Thorac Cardiovasc Surg. 1984 Sep;88(3):324-33. J Thorac Cardiovasc Surg. 1984. PMID: 6381888 Review.
Cited by
-
Thrombotic complications after valve replacement with porcine heterografts.World J Surg. 1979 Aug 31;3(4):505-10. doi: 10.1007/BF01556120. World J Surg. 1979. PMID: 516769 No abstract available.
-
Clinical experience with the Ionescu-Shiley xenograft valve: four to five-year follow-up.Tex Heart Inst J. 1982 Sep;9(3):285-92. Tex Heart Inst J. 1982. PMID: 15226928 Free PMC article.
-
Multiple valve replacement with pericardial xenograft. Clinical and haemodynamic study.Br Heart J. 1980 Nov;44(5):534-40. doi: 10.1136/hrt.44.5.534. Br Heart J. 1980. PMID: 7437194 Free PMC article.
-
Chordal rupture. II: comparison between repair and replacement.Br Heart J. 1983 Oct;50(4):318-24. doi: 10.1136/hrt.50.4.318. Br Heart J. 1983. PMID: 6626392 Free PMC article.
-
Influence of fixation conditions on the performance of glutaraldehyde-treated porcine aortic valves: towards a more scientific basis.Thorax. 1979 Apr;34(2):166-76. doi: 10.1136/thx.34.2.166. Thorax. 1979. PMID: 113899 Free PMC article.