. 1971 Apr;46(246):152-9.
doi: 10.1136/adc.46.246.152.

Effect of alterations in mechanical ventilator settings on pulmonary gas exchange in hyaline membrane disease

Effect of alterations in mechanical ventilator settings on pulmonary gas exchange in hyaline membrane disease

E O Reynolds. Arch Dis Child. 1971 Apr.

Abstract

The effect of altering peak airway pressure, respiratory frequency, and inspiration: expiration ratio on arterial blood gas tensions, blood pressure, and calculated right-to-left shunt was investigated in 6 infants undergoing mechanical ventilation for hyaline membrane disease with a Bennet ventilator. The use of a very long inspiratory phase resulted in a large increase in Pao2 and fall in right-to-left shunt without affecting mean arterial blood pressure.