Application of Fourier analysis to the visibility of gratings
- PMID: 5666169
- PMCID: PMC1351748
- DOI: 10.1113/jphysiol.1968.sp008574
Application of Fourier analysis to the visibility of gratings
Abstract
1. The contrast thresholds of a variety of grating patterns have been measured over a wide range of spatial frequencies.2. Contrast thresholds for the detection of gratings whose luminance profiles are sine, square, rectangular or saw-tooth waves can be simply related using Fourier theory.3. Over a wide range of spatial frequencies the contrast threshold of a grating is determined only by the amplitude of the fundamental Fourier component of its wave form.4. Gratings of complex wave form cannot be distinguished from sine-wave gratings until their contrast has been raised to a level at which the higher harmonic components reach their independent threshold.5. These findings can be explained by the existence within the nervous system of linearly operating independent mechanisms selectively sensitive to limited ranges of spatial frequencies.
Similar articles
-
A comparison of threshold and suprathreshold appearance of gratings with components in the low and high spatial frequency range.J Physiol. 1978 Nov;284:193-201. doi: 10.1113/jphysiol.1978.sp012535. J Physiol. 1978. PMID: 731527 Free PMC article.
-
Responses of striate cortex cells to grating and checkerboard patterns.J Physiol. 1979 Jun;291:483-505. doi: 10.1113/jphysiol.1979.sp012827. J Physiol. 1979. PMID: 113531 Free PMC article.
-
Nonlinear analysis of spatial vision using first-and-second-order Volterra transfer functions measurement.Vision Res. 1990;30(12):2031-57. doi: 10.1016/0042-6989(90)90019-h. Vision Res. 1990. PMID: 2288104
-
Spatial waveform discrimination following higher-harmonic adaptation.J Opt Soc Am A. 1988 Oct;5(10):1744-8. doi: 10.1364/josaa.5.001744. J Opt Soc Am A. 1988. PMID: 3204437
-
Evidence for a common motion mechanism of luminance-modulated and contrast-modulated patterns: selective adaptation.Perception. 1991;20(4):455-66. doi: 10.1068/p200455. Perception. 1991. PMID: 1771131
Cited by
-
Investigating the link between radiologists' gaze, diagnostic decision, and image content.J Am Med Inform Assoc. 2013 Nov-Dec;20(6):1067-75. doi: 10.1136/amiajnl-2012-001503. Epub 2013 Jun 20. J Am Med Inform Assoc. 2013. PMID: 23788627 Free PMC article.
-
Ocular findings in patients with attention deficit and hyperactivity.Int Ophthalmol. 2020 Nov;40(11):3105-3113. doi: 10.1007/s10792-020-01497-z. Epub 2020 Jul 14. Int Ophthalmol. 2020. PMID: 32666167
-
Spatial frequency tuning of single units in macaque supragranular striate cortex.Proc Natl Acad Sci U S A. 1991 Aug 15;88(16):7066-70. doi: 10.1073/pnas.88.16.7066. Proc Natl Acad Sci U S A. 1991. PMID: 1651492 Free PMC article.
-
The detection of gratings by independent activation of line detectors.J Physiol. 1975 May;247(2):237-71. doi: 10.1113/jphysiol.1975.sp010930. J Physiol. 1975. PMID: 1151774 Free PMC article.
-
Visual resolution, contrast sensitivity, and the cortical magnification factor.Exp Brain Res. 1979;37(3):475-94. doi: 10.1007/BF00236818. Exp Brain Res. 1979. PMID: 520438
References
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical