. 1968 May;8(5):596-607.
doi: 10.1016/S0006-3495(68)86510-5.

Computation of impulse conduction in myelinated fibers; theoretical basis of the velocity-diameter relation

Computation of impulse conduction in myelinated fibers; theoretical basis of the velocity-diameter relation

L Goldman et al. Biophys J. 1968 May.

Abstract

For myelinated fibers, it is experimentally well established that spike conduction velocity is proportional to fiber diameter. However no really satisfactory theoretical treatment has been proposed. To treat this problem a theoretical axon was described consisting of lengths of passive leaky cable (internode) regularly interrupted by short isopotential patches of excitable membrane (node). The nodal membrane was assumed to obey the Frankenhaeuser-Huxley equations. The explicit diameter dependencies of the various parameters were incorporated into the equations. The fiber diameter to axon diameter ratio was taken to be constant, and the internode length was taken to be proportional to the fiber diameter. Both these conditions reflect the situation that exists in real, experimental fibers. Dimensional analysis shows that these anatomical conditions are equivalent to Rushton's (1951) assumption of corresponding states. Hence, conduction velocity will be proportional to fiber diameter, in complete agreement with the experimental findings. Digital computer solutions of these equations were made in order to compute a set of actual velocities. Computations made with constant internode length or constant myelin thickness (i.e., nonconstant fiber diameter to axon diameter ratio) did not show linearity of the velocity-diameter relation.

PubMed Disclaimer

References

    1. J Physiol. 1959 Oct;148:188-200 - PubMed
    1. J Physiol. 1949 May 15;108(3):315-39 - PubMed
    1. J Anat. 1949 Oct;83(4):336-50, pl - PubMed
    1. J Physiol. 1951 Sep;115(1):101-22 - PubMed
    1. Mayo Clin Proc. 1966 Nov;41(11):778-84 - PubMed