Pulmonary artery flow-guided catheters in the perioperative period. Indications and complications
- PMID: 577248
Pulmonary artery flow-guided catheters in the perioperative period. Indications and complications
Abstract
The risk factor of pulmonary artery catheterization was assessed in 392 critically ill patients. Major indications for catheterization in the operating room were marginal cardiovascular reserve, anticipated large fluid and blood loss, and hypotensive anesthesia. Immediate complications included cardiac arrhythmia, carotid artery puncture, and pneumotherax. Long-term complications included positive bacterial cultures, pulmonary infarction and neuropathy. None of the complications were directly responsible for the deaths in this series. Pulmonary artery monitoring in critically ill persons is a relatively safe procedure.
Similar articles
-
A prospective analysis of 1,400 pulmonary artery catheterizations in patients undergoing cardiac surgery.Acta Anaesthesiol Scand. 1986 Jul;30(5):386-92. doi: 10.1111/j.1399-6576.1986.tb02436.x. Acta Anaesthesiol Scand. 1986. PMID: 3766094
-
Complications of pulmonary artery catheterization in the care of critically ill patients. A prospective study.Chest. 1979 Dec;76(6):647-52. doi: 10.1378/chest.76.6.647. Chest. 1979. PMID: 510002
-
[Puncture of the subclavian vein. Indications, technic and complications in 523 cases].Z Gesamte Inn Med. 1972 Jun 1;27(11):486-90. Z Gesamte Inn Med. 1972. PMID: 5055967 German. No abstract available.
-
Complications associated with the adult respiratory distress syndrome.Clin Chest Med. 1982 Jan;3(1):143-55. Clin Chest Med. 1982. PMID: 7042184 Review.
-
[Complications of catheterization of the central veins].Vestn Akad Med Nauk SSSR. 1986;(7):89-94. Vestn Akad Med Nauk SSSR. 1986. PMID: 3529698 Review. Russian. No abstract available.
Cited by
-
Pulmonary artery catheter infections. A prospective study.Ann Surg. 1985 Feb;201(2):237-41. doi: 10.1097/00000658-198502000-00018. Ann Surg. 1985. PMID: 3882064 Free PMC article.
-
Swan-Ganz catheter contamination: a protective sleeve for repositioning.Can Anaesth Soc J. 1981 Jan;28(1):86-8. doi: 10.1007/BF03007298. Can Anaesth Soc J. 1981. PMID: 7237210
-
Perforation of the pulmonary artery requiring pneumonectomy after the use of a flow-directed (Swan-Ganz) catheter.Thorax. 1979 Aug;34(4):550-3. doi: 10.1136/thx.34.4.550. Thorax. 1979. PMID: 505355 Free PMC article.
-
Pulmonary artery catheter induced pulmonary artery rupture in patients undergoing cardiac surgery.Can Anaesth Soc J. 1985 May;32(3 Pt 1):258-64. doi: 10.1007/BF03015139. Can Anaesth Soc J. 1985. PMID: 3873982
-
The Use of Pulmonary Artery Catheter in Sepsis Patients: A Literature Review.J Clin Med Res. 2016 Nov;8(11):769-776. doi: 10.14740/jocmr2719w. Epub 2016 Sep 29. J Clin Med Res. 2016. PMID: 27738477 Free PMC article. Review.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources