Elastic constants of the human lens capsule
- PMID: 5773553
- PMCID: PMC1351628
- DOI: 10.1113/jphysiol.1969.sp008739
Elastic constants of the human lens capsule
Abstract
1. A technique is described whereby the elasticity of the human lens capsule has been determined at birth and throughout life. This technique requires three separate determinations: (a) thickness; (b) stress and strain; (c) Poisson's ratio; (a) the capsule was clamped between accurately perforated ground glass plates and its thickness determined by noting the change in depth of focus between Latex spherules adhering to its upper and lower surfaces; (b) the undisturbed capsule was then placed in a specially designed glass distension apparatus and the relationship between volume and pressure recorded when it was distended with isotonic saline. The permeability of the capsule was also measured; (c) in some cases Poisson's ratio was determined by measuring the change of thickness of the capsule and the height to which it rose when distended with isotonic saline at different pressures. An apparatus was designed for this purpose.2. The average thickness of the anterior capsule increases from birth until about the 60th year but thereafter it decreases slightly.3. Poisson's ratio was about 0.47 for both cat and human capsule, and no significant variations with age in human capsule could be detected.4. Corrected volume pressure curves obeyed Hook's law almost to the point of capsule rupture.5. In childhood Young's Modulus of elasticity is about 6 x 10(7) dyn/cm(2) and decreases to 3 x 10(7) dyn/cm(2) at 60 and 1.5 x 10(7) dyn/cm(2) in extreme old age.6. The ultimate tensile stress was 2.3 x 10(7) dyn/cm(2) in young capsules and 0.7 x 10(7) dyn/cm(2) in old ones. The maximum percentage elongation was 29 per cent and independent of age.7. The implications of these findings are discussed in relation to(a) the mechanical properties of the lens capsule;(b) the ageing of the lens capsule and basement membranes; and(c) the decrease in elasticity of the lens capsule as a cause of presbyopia.
Similar articles
-
Biomechanical characteristics of the human anterior lens capsule in relation to age.Invest Ophthalmol Vis Sci. 1997 Feb;38(2):357-63. Invest Ophthalmol Vis Sci. 1997. PMID: 9040468
-
Thickness and volume constants and ultrastructural organization of basement membrane (lens capsule).J Physiol. 1979 Aug;293:229-45. doi: 10.1113/jphysiol.1979.sp012887. J Physiol. 1979. PMID: 501593 Free PMC article.
-
The significance of the shape of the lens and capsular energy changes in accommodation.J Physiol. 1969 Mar;201(1):21-47. doi: 10.1113/jphysiol.1969.sp008740. J Physiol. 1969. PMID: 5775812 Free PMC article.
-
Biomechanical properties of the lens capsule: A review.J Mech Behav Biomed Mater. 2020 Mar;103:103600. doi: 10.1016/j.jmbbm.2019.103600. Epub 2019 Dec 14. J Mech Behav Biomed Mater. 2020. PMID: 32090929 Review.
-
[Aging of the crystalline lens and presbyopia].Tijdschr Gerontol Geriatr. 1998 Aug;29(4):185-8. Tijdschr Gerontol Geriatr. 1998. PMID: 9746933 Review. Dutch.
Cited by
-
Gradient moduli lens models: how material properties and application of forces can affect deformation and distributions of stress.Sci Rep. 2016 Aug 10;6:31171. doi: 10.1038/srep31171. Sci Rep. 2016. PMID: 27507665 Free PMC article.
-
Translating ocular biomechanics into clinical practice: current state and future prospects.Curr Eye Res. 2015 Jan;40(1):1-18. doi: 10.3109/02713683.2014.914543. Epub 2014 May 15. Curr Eye Res. 2015. PMID: 24832392 Free PMC article. Review.
-
Age-related changes in centripetal ciliary body movement relative to centripetal lens movement in monkeys.Exp Eye Res. 2009 Dec;89(6):824-32. doi: 10.1016/j.exer.2009.07.009. Epub 2009 Jul 25. Exp Eye Res. 2009. PMID: 19635475 Free PMC article.
-
Tissue, cellular, and molecular level determinants for eye lens stiffness and elasticity.Front Ophthalmol (Lausanne). 2024 Aug 8;4:1456474. doi: 10.3389/fopht.2024.1456474. eCollection 2024. Front Ophthalmol (Lausanne). 2024. PMID: 39176256 Free PMC article. Review.
-
Measurements of elastic modulus for human anterior lens capsule with atomic force microscopy: the effect of loading force.Int Ophthalmol. 2014 Jun;34(3):519-23. doi: 10.1007/s10792-013-9846-z. Epub 2013 Sep 15. Int Ophthalmol. 2014. PMID: 24037592
References
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Miscellaneous