Amniocentesis in early pregnancy using free-hand needle technique under ultrasonic control
- PMID: 6119247
- DOI: 10.1016/0020-7292(81)90055-2
Amniocentesis in early pregnancy using free-hand needle technique under ultrasonic control
Abstract
A study of 164 patients who had amniocentesis using free-hand needle technique under ultrasonic control showed that the rate of abortion was only 2.9% following single puncture as compared with 4.5% following multiple puncture. Only 1.2% had an abortion when the amniotic fluid was clear, whereas 2.4% had an abortion when the amniotic fluid was colored brown. Only 4 of 8 miscarriages (2.43%) may be related to previous amniocentesis since this occurred within 3 weeks following the procedure. The overall perinatal mortality rate in this group was 2.44% though only one of 164 (0.6%) may be attributed to amniocentesis. One baby (0.6%) had talipes equinovarus.
Similar articles
-
[Amniocentesis in the 2d trimenon: comparison of 2 technics].Geburtshilfe Frauenheilkd. 1987 Jun;47(6):393-4. doi: 10.1055/s-2008-1036142. Geburtshilfe Frauenheilkd. 1987. PMID: 3305143 German.
-
Diagnostic mid trimester amniocentesis: how safe?Am J Obstet Gynecol. 2004 Aug;191(2):607-15. doi: 10.1016/j.ajog.2004.05.078. Am J Obstet Gynecol. 2004. PMID: 15343248 Review.
-
Randomised controlled trial of genetic amniocentesis in 4606 low-risk women.Lancet. 1986 Jun 7;1(8493):1287-93. doi: 10.1016/s0140-6736(86)91218-3. Lancet. 1986. PMID: 2423826 Clinical Trial.
-
Analysis of 2136 genetic amniocenteses: experience of a single physician.Am J Obstet Gynecol. 1985 Jun 15;152(4):436-43. doi: 10.1016/s0002-9378(85)80154-x. Am J Obstet Gynecol. 1985. PMID: 4014336
-
[Complications from chorionic villus sampling and amniocentesis].J Gynecol Obstet Biol Reprod (Paris). 1994;23(5):476-80. J Gynecol Obstet Biol Reprod (Paris). 1994. PMID: 7983305 Review. French. No abstract available.
MeSH terms