Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1977 Dec:21:239-45.
doi: 10.1289/ehp.7721239.

Metabolism of trichloroethylene and tetrachloroethylene in human subjects

Metabolism of trichloroethylene and tetrachloroethylene in human subjects

M Ikeda. Environ Health Perspect. 1977 Dec.

Abstract

A linear correlation exists between the trichloroethylene concentration in the work environments and the level of total trichloro compounds in the urine of the workers, as expressed by the equation: Gamma = 7.25=chi + 5.5, where Gamma is trichloroethylene in air (ppm) is Chi is total trichloro compounds in urine (mg/l). Trichloroethanol level is also linearly related to trichloroethylene concentration, while trichloroacetic acid level deviates from the linear relation when trichloroethylene level exceeds 50 ppm. In the case of tetrachloroethylene exposure, both trichloroethanol and trichloroacetic acid levels, and consequently the total trichloro compound level, reach a plateau at tetrachloroethylene level well below 100 ppm. The mean urinary biological half-life is 41 hr for trichloroethylene and 144 hr for tetrachloroethylene. The two values are the largest of the values so far obtained with organic solvents. The respiratory half-life is shorter than the urinary half-life, both in richloroethylene and in tetrachloroethylene. Applications of the urinalyses in clinical cases are described. In one case of trichlorethylene dependency, a longer urinary half-life of 73 hr was observed. An automated system is presented for the determination of total trichloro compounds in human urine. The system can analyze the samples at the rate of 20 samples per hour with an accuracy comparable to that of the time-consuming manual analysis.

PubMed Disclaimer

Similar articles

Cited by

References

    1. AMA Arch Ind Health. 1956 Jun;13(6):581-92 - PubMed
    1. Biochem Pharmacol. 1963 Aug;12:795-802 - PubMed
    1. Br J Ind Med. 1962 Apr;19:134-41 - PubMed
    1. Nature. 1961 Aug 19;191:820 - PubMed
    1. Br J Ind Med. 1971 Oct;28(4):386-91 - PubMed

LinkOut - more resources