How far is the cardiac output?
- PMID: 6149404
- DOI: 10.1016/s0140-6736(84)91118-8
How far is the cardiac output?
Abstract
Measurement of volumetric cardiac output is technically difficult and poorly reproducible, and the technique is unsuitable for use in the majority of patients in whom a knowledge of overall cardiovascular function would be desirable. Interpretation of a single measurement in a patient is difficult because little is known about volumetric cardiac output in normal subjects and the available techniques of measurement are very complex or invasive. Linear cardiac output, in contrast, can be simply, non-invasively, and reproducibly measured at the bedside by doppler ultrasound. The systolic-velocity integral of a single heart beat (stroke distance) multiplied by the heart rate gives minute distance; this may be envisaged as the distance travelled by mid-stream blood in the aorta in a minute. Providing there is no aortic disease, minute distance may be used as an absolute indication of cardiac output and for following serial changes.
Similar articles
-
Reproducibility of linear cardiac output measurement by Doppler ultrasound alone.Br Heart J. 1986 Jan;55(1):25-31. doi: 10.1136/hrt.55.1.25. Br Heart J. 1986. PMID: 3511929 Free PMC article.
-
Non-invasive assessment of cardiac output in children.J Accid Emerg Med. 1998 Sep;15(5):304-7. doi: 10.1136/emj.15.5.304. J Accid Emerg Med. 1998. PMID: 9785155 Free PMC article.
-
Assessment of cardiac output by the Doppler ultrasound technique alone.Br Heart J. 1985 Feb;53(2):123-9. doi: 10.1136/hrt.53.2.123. Br Heart J. 1985. PMID: 3881107 Free PMC article.
-
Noninvasive measurement of cardiac output by continuous-wave Doppler echocardiography: initial experience and review of the literature.Mayo Clin Proc. 1984 Jul;59(7):484-9. doi: 10.1016/s0025-6196(12)60438-8. Mayo Clin Proc. 1984. PMID: 6738114
-
[Noninvasive measurement of cardiac output by pulsed Doppler echocardiography. Correlation with thermodilution].Arch Mal Coeur Vaiss. 1990 Feb;83(2):237-44. Arch Mal Coeur Vaiss. 1990. PMID: 2106860 Review. French.
Cited by
-
Accuracy of an indirect carbon dioxide Fick method in determination of the cardiac output in critically ill mechanically ventilated patients.Intensive Care Med. 1988;14(2):131-5. doi: 10.1007/BF00257466. Intensive Care Med. 1988. PMID: 3129478
-
Delay between the onset of symptoms of acute myocardial infarction and seeking medical assistance is influenced by left ventricular function at presentation.Br Heart J. 1995 Feb;73(2):125-8. doi: 10.1136/hrt.73.2.125. Br Heart J. 1995. PMID: 7696020 Free PMC article.
-
Suprasternal Doppler ultrasound for assessment of stroke distance.Arch Dis Child. 1998 Sep;79(3):251-5. doi: 10.1136/adc.79.3.251. Arch Dis Child. 1998. PMID: 9875022 Free PMC article.
-
Reference values of aortic flow velocity integral in 1193 healthy infants, children, and adolescents to quickly estimate cardiac stroke volume.Pediatr Cardiol. 2013 Jun;34(5):1194-200. doi: 10.1007/s00246-012-0628-6. Epub 2013 Jan 24. Pediatr Cardiol. 2013. PMID: 23344893
-
What is meant by a "controlled" ventricular rate in atrial fibrillation?Br Heart J. 1990 Mar;63(3):157-61. doi: 10.1136/hrt.63.3.157. Br Heart J. 1990. PMID: 2183858 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources