The chronaxie time and its practical importance
- PMID: 6160523
- DOI: 10.1111/j.1540-8159.1980.tb05236.x
The chronaxie time and its practical importance
Abstract
Describing mathematically, the intensity duration curves of electrostimulation by hyperbolas, Lapicque introduced two terms which characterized the functional relationship: "Rheobase" was the lowest intensity with indefinite pulse duration which just stimulated muscles or nerves. "Chronaxie" was that pulse duration at which the threshold intensity was twice that of the rheobase. Up to now, both terms have never played an important role in cardiac pacing. However, it can be shown that the chronaxie, especially, is an important parameter--influenced by several factors such as electrode size, material, and stimulation mode--which may help match the generator to its electrode. Practical consequences may be derived from the concept of chronaxie: 1) A pulse duration longer than the chronaxie is not desirable because current consumption is increased without decreasing the threshold significantly. 2) Pacing with constant current needs twice that pulse duration of constant voltage stimulation. 3) Smaller electrodes are more favorable because the pulse duration they need may be reduced without losing safety. 4) Estimation of the safety margin with decreasing output of the generator or with programmable pulse duration is possible if the chronaxie of a specific electrode is known.
Similar articles
-
The strength-duration curve and its importance in pacing efficiency: a study of 325 pacing leads in 229 patients.Pacing Clin Electrophysiol. 2000 Aug;23(8):1273-7. doi: 10.1111/j.1540-8159.2000.tb00943.x. Pacing Clin Electrophysiol. 2000. PMID: 10962751
-
Effect of pacing rate on the human atrial strength-duration curve.J Am Coll Cardiol. 1990 Jun;15(7):1618-23. doi: 10.1016/0735-1097(90)92835-p. J Am Coll Cardiol. 1990. PMID: 2345243
-
Chronaxie calculated from current-duration and voltage-duration data.J Neurosci Methods. 2000 Apr 1;97(1):45-50. doi: 10.1016/s0165-0270(00)00163-1. J Neurosci Methods. 2000. PMID: 10771074 Clinical Trial.
-
Accuracy limitations of chronaxie values.IEEE Trans Biomed Eng. 2004 Jan;51(1):176-81. doi: 10.1109/TBME.2003.820340. IEEE Trans Biomed Eng. 2004. PMID: 14723507 Review.
-
Which elements are excited in electrical stimulation of mammalian central nervous system: a review.Brain Res. 1975 Nov 21;98(3):417-40. doi: 10.1016/0006-8993(75)90364-9. Brain Res. 1975. PMID: 1102064 Review.
Cited by
-
Influence of peripheral axon geometry and local anatomy on magnetostimulation chronaxie.J Neural Eng. 2024 Jun 11;21(3):10.1088/1741-2552/ad510a. doi: 10.1088/1741-2552/ad510a. J Neural Eng. 2024. PMID: 38806036 Free PMC article.
-
Safety considerations concerning the minimum threshold for magnetic excitation of the heart.Med Biol Eng Comput. 1993 Nov;31(6):651-4. doi: 10.1007/BF02441818. Med Biol Eng Comput. 1993. PMID: 8145596 No abstract available.
-
Easy method to examine single nerve fiber excitability and conduction parameters using intact nonanesthetized earthworms.Adv Physiol Educ. 2014 Sep;38(3):253-64. doi: 10.1152/advan.00137.2013. Adv Physiol Educ. 2014. PMID: 25179616 Free PMC article.
-
Cortical neuron activation induced by electromagnetic stimulation: a quantitative analysis via modelling and simulation.J Comput Neurosci. 2016 Feb;40(1):51-64. doi: 10.1007/s10827-015-0585-1. Epub 2015 Dec 30. J Comput Neurosci. 2016. PMID: 26719168
-
Werner Irnich und die Entwicklung des Zweikammer-Herzschrittmachers : Ein Nachruf.Herzschrittmacherther Elektrophysiol. 2025 Aug 18. doi: 10.1007/s00399-025-01105-6. Online ahead of print. Herzschrittmacherther Elektrophysiol. 2025. PMID: 40824398 German. No abstract available.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical