Insensible perspiration from the skin under standardized environmental conditions
- PMID: 616059
- DOI: 10.3109/00365517709092637
Insensible perspiration from the skin under standardized environmental conditions
Abstract
The cutaneous insensible perspiration of adult healthy volunteers was measured by a new method based on estimation of the vapour pressure gradient in the air layer immediately adjacent to skin. All measurements were performed at ambient temperatures of 22 degrees, 27 degrees and 30 degrees C and at a relative humidity of 30%. On the basis of the results obtained the total body surface area of the investigated subjects was divided into four different zones with respect to quantitative water loss. The percentage contribution of the different zones to the total cutaneous water loss proved to be fairly independent of the amibent temperature. The average total cutaneous insensible perspiration of a naked resting subject with a body surface area of 1.75 m2 was estimated to be 381 +/- 18, 526 +/- 25 and 695 +/- 35 ml per day (mean values +/- SEE) at an ambient temperature of 22 degrees C, 27 degrees C and 30 degrees C, respectively. By recording the evaporation rate from only three separate measurement points, it was possible to calculate the total cutaneous insensible water loss with good accuracy.
Similar articles
-
Measurement of water transport through the skin.Ups J Med Sci. 1981;86(1):23-6. doi: 10.3109/03009738109179206. Ups J Med Sci. 1981. PMID: 7303329
-
Transepidermal water loss in newborn infants. I. Relation to ambient humidity and site of measurement and estimation of total transepidermal water loss.Acta Paediatr Scand. 1977 Sep;66(5):553-62. doi: 10.1111/j.1651-2227.1977.tb07946.x. Acta Paediatr Scand. 1977. PMID: 899773
-
Insensible perspiration during anaesthesia and surgery.Acta Anaesthesiol Scand. 1980 Oct;24(5):362-6. doi: 10.1111/j.1399-6576.1980.tb01564.x. Acta Anaesthesiol Scand. 1980. PMID: 7468126
-
The stress of hot environments.Monogr Physiol Soc. 1972;(29):1-312. Monogr Physiol Soc. 1972. PMID: 4620406 Review. No abstract available.
-
Human perspiration measurement.Physiol Meas. 1998 Nov;19(4):449-61. doi: 10.1088/0967-3334/19/4/001. Physiol Meas. 1998. PMID: 9863672 Review.
Cited by
-
[Determinants of insensible fluid loss. Perspiration, protein shift and endothelial glycocalyx].Anaesthesist. 2007 Aug;56(8):747-58, 760-4. doi: 10.1007/s00101-007-1235-4. Anaesthesist. 2007. PMID: 17684711 Review. German.
-
Loss or Dilution-A New Diagnostic Method to Assess the Impact of Dilution on Standard Laboratory Parameters.Diagnostics (Basel). 2023 Aug 4;13(15):2596. doi: 10.3390/diagnostics13152596. Diagnostics (Basel). 2023. PMID: 37568959 Free PMC article.
-
Perioperative restrictive versus goal-directed fluid therapy for adults undergoing major non-cardiac surgery.Cochrane Database Syst Rev. 2019 Dec 12;12(12):CD012767. doi: 10.1002/14651858.CD012767.pub2. Cochrane Database Syst Rev. 2019. PMID: 31829446 Free PMC article.
-
Has goal directed fluid therapy and glycocalyx a role in enhanced recovery after anesthesia?Saudi J Anaesth. 2017 Oct-Dec;11(4):381-383. doi: 10.4103/sja.SJA_456_17. Saudi J Anaesth. 2017. PMID: 29033715 Free PMC article. No abstract available.
-
Measurement of water exchange through skin.Med Biol Eng Comput. 1977 May;15(3):209-18. doi: 10.1007/BF02441040. Med Biol Eng Comput. 1977. PMID: 195148 No abstract available.
MeSH terms