Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1982 Jun-Sep;4(2-3):177-209.
doi: 10.1007/BF02918312.

Influence of external concentration fluctuations on leukocyte chemotactic orientation

Influence of external concentration fluctuations on leukocyte chemotactic orientation

D A Lauffenburger. Cell Biophys. 1982 Jun-Sep.

Abstract

The quantitative dependence of leukocyte chemotactic orientation on imprecision in the measurement of chemoattractant concentrations from thermal fluctuations is analyzed. First, a mathematical model relating orientation to differences in receptor occupancy across cell dimensions is developed. This is then coupled with an extension of Berg and Purcell's analysis (1) of the precision of attractant concentration measurements by means of receptor occupancy. Our results show that thermal fluctuations in external concentrations can limit the accuracy of orientation, unless the measurement noise is reduced by averaging the measurements over a period of time. Comparison of our model predictions to experimental orientation data suggests that leukocytes do overcome this limitation, and allows estimation of the time-averaging period necessary to do so. For the orientation observed in a visual bridge assay by Zigmond (2) using the attractant peptide FNLLP, we estimate that receptor occupancy measurements for spatial comparison across cell dimensions must be averaged for a few minutes. Otherwise, the fluctuations in the attractant concentration near the cell will be too great to allow the observed degree of orientation. Our analysis also suggests that the ratio of signal-to-signal noise does not adequately characterize orientation accuracy. Accurate orientation can, in some situations, occur when this ratio is substantially less than unity; in other situations, a ratio much greater than unity is required for accurate orientation.

PubMed Disclaimer

References

    1. Science. 1981 Aug 21;213(4510):830-7 - PubMed
    1. Cell Biophys. 1982 Jun-Sep;4(2-3):211-29 - PubMed
    1. J Cell Biol. 1981 Mar;88(3):644-7 - PubMed
    1. J Immunol Methods. 1981;40(1):45-60 - PubMed
    1. Q Rev Biophys. 1980 May;13(2):201-30 - PubMed

Publication types

Substances