Closure of lung leaks by fibrin gluing. Experimental investigations and clinical experience
- PMID: 6192531
- DOI: 10.1055/s-2007-1021976
Closure of lung leaks by fibrin gluing. Experimental investigations and clinical experience
Abstract
In 28 male Wistar rats a standardized lung incision was closed by running suture and in half of the animals by additional application of fibrin adhesive. The animals were sacrificed 30 minutes and 5 days postoperatively. A significantly higher tolerance to increased inflation pressure was found in the fibrin-treated group. Ten patients undergoing pulmonary resection had conventional closure of parenchymatous lesions with additional fibrin gluing. Under positive air way pressure ventilation the sealing effect proved to be better after application of fibrin adhesive to the sutured area.
Similar articles
-
[Closure of pleura and lung lesions with fibrin adhesive. Experimental studies].Zentralbl Chir. 1982;107(16):1016-21. Zentralbl Chir. 1982. PMID: 7148194 German.
-
Experimental gluing of lung parenchyma in rats.Thorac Cardiovasc Surg. 1997 Apr;45(2):83-7. doi: 10.1055/s-2007-1013693. Thorac Cardiovasc Surg. 1997. PMID: 9175225
-
Prevention of peritoneal adhesion formation by fibrin sealant. An experimental study in rats.Ann Chir Gynaecol. 1984;73(1):11-3. Ann Chir Gynaecol. 1984. PMID: 6610380
-
Tissue adhesives and intestinal anastomosis.Ann Chir Gynaecol. 1986;75(4):205-8. Ann Chir Gynaecol. 1986. PMID: 3535618 Review.
-
Protein-based medical adhesives.Trends Biotechnol. 1990 Feb;8(2):53-7. doi: 10.1016/0167-7799(90)90134-j. Trends Biotechnol. 1990. PMID: 1366498 Review.
Cited by
-
The efficacy and side effects of gelatin-resorcinol formaldehyde-glutaraldehyde (GRFG) glue for preventing and sealing pulmonary air leakage.Surg Today. 2000;30(3):244-8. doi: 10.1007/s005950050053. Surg Today. 2000. PMID: 10752777 Clinical Trial.
-
Bronchopleural fistula after pneumonectomy.Thorax. 1986 Nov;41(11):896. doi: 10.1136/thx.41.11.896-a. Thorax. 1986. PMID: 3824279 Free PMC article. No abstract available.
-
Use of biological glue to control pulmonary air leaks.Thorax. 1990 Sep;45(9):670-4. doi: 10.1136/thx.45.9.670. Thorax. 1990. PMID: 2218973 Free PMC article.
-
Which bioabsorbable sheet is optimal for combined application with fibrin sealant against alveolar air leakage?J Thorac Dis. 2023 Oct 31;15(10):5442-5453. doi: 10.21037/jtd-23-773. Epub 2023 Sep 25. J Thorac Dis. 2023. PMID: 37969310 Free PMC article.