Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1984 Jun 10;259(11):6890-5.

Inhibition of human activated Factor X by antithrombin III and alpha 1-proteinase inhibitor in human plasma

  • PMID: 6202686
Free article

Inhibition of human activated Factor X by antithrombin III and alpha 1-proteinase inhibitor in human plasma

S N Gitel et al. J Biol Chem. .
Free article

Abstract

The inhibition of activated human Factor X by human plasma protease inhibitors was investigated in both purified and plasma systems. In the former, antithrombin III, alpha 1-proteinase inhibitor, and alpha 2-macroglobulin, at normal plasma concentrations, markedly inhibited activated Factor X. Significant inhibition by alpha 2-antiplasmin, however, was only achieved when present at 40 times its plasma concentration. The relative rates of inhibition of activated Factor X coagulant activity in normal human plasma, antithrombin III-deficient plasma, and alpha 1-proteinase inhibitor-deficient plasma were 1.0, 0.63, and 0.75, respectively. From these relative rates of inhibition and their measured concentrations in the 3 plasmas, it was calculated that antithrombin III, alpha 1-proteinase inhibitor, and alpha 2-macroglobulin contribute 53, 35, and 12%, respectively, to the inhibition of activated Factor X in normal human plasma. Using 125I-labeled activated Factor X and a combination of sodium dodecyl sulfate disc gel electrophoresis and immunoadsorption, it was then demonstrated that antithrombin III accounted for 45-55%, alpha 1-proteinase inhibitor, 35-40%, and alpha 2-macroglobulin, 10-15% of the inhibition of the labeled protease in normal human plasma. The values obtained with the deficient plasmas are consistent with the distribution of activated Factor X-inhibitor complexes in normal human plasma. These data show by two independent techniques, one measuring coagulant activity and the other 125I-labeled activated Factor X-inhibitor complexes, that both antithrombin III and alpha 1-proteinase inhibitor are the major inhibitors of activated Factor X in normal human plasma.

PubMed Disclaimer

Publication types

LinkOut - more resources