Cardiac imaging using gated magnetic resonance
- PMID: 6227934
- DOI: 10.1148/radiology.150.1.6227934
Cardiac imaging using gated magnetic resonance
Abstract
To overcome the limitations of magnetic resonance (MR) cardiac imaging using nongated data acquisition, three methods for acquiring a gating signal, which could be applied in the presence of a magnetic field, were tested: an air-filled plethysmograph, a laser-Doppler capillary perfusion flowmeter, and an electrocardiographic gating device. The gating signal was used for timing of MR imaging sequences (IS). Application of each gating method yielded significant improvements in structural MR image resolution of the beating heart, although with both plethysmography and laser-Doppler velocimetry it was difficult to obtain cardiac images from the early portion of the cardiac cycle due to an intrinsic delay between the ECG R wave and peripheral detection of the gating signal. Variations in the temporal relationship between the R wave and plethysmographic and laser-Doppler signals produced inconsistencies in the timing of IS. Since the ECG signal is virtually free of these problems, the preferable gating technique is IS synchronization with an electrocardiogram. The gated images acquired with this method provide sharp definition of internal cardiac morphology and can be temporarily referenced to end diastole and end systole or intermediate points.
Similar articles
-
ECG-synchronized cardiac MR imaging: method and evaluation.Radiology. 1985 Jun;155(3):681-6. doi: 10.1148/radiology.155.3.4001369. Radiology. 1985. PMID: 4001369
-
ECG-triggered NMR imaging of the heart.Diagn Imaging Clin Med. 1984;53(1):29-37. Diagn Imaging Clin Med. 1984. PMID: 6559126
-
Feasibility of cardiac gating free of interference with electro-magnetic fields at 1.5 Tesla, 3.0 Tesla and 7.0 Tesla using an MR-stethoscope.Invest Radiol. 2009 Sep;44(9):539-47. doi: 10.1097/RLI.0b013e3181b4c15e. Invest Radiol. 2009. PMID: 19652614
-
Cardiac MR imaging: a guide for the beginner.Radiographics. 1999 Jul-Aug;19(4):1009-25; discussion 1026-8. doi: 10.1148/radiographics.19.4.g99jl161009. Radiographics. 1999. PMID: 10464806 Review.
-
Cardiovascular applications of magnetic resonance imaging.CMAJ. 1985 Dec 1;133(11):1121-5. CMAJ. 1985. PMID: 3904969 Free PMC article. Review.
Cited by
-
Cardiac-Gated En Face Doppler Measurement of Retinal Blood Flow Using Swept-Source Optical Coherence Tomography at 100,000 Axial Scans per Second.Invest Ophthalmol Vis Sci. 2015 Apr;56(4):2522-30. doi: 10.1167/iovs.14-16119. Invest Ophthalmol Vis Sci. 2015. PMID: 25744974 Free PMC article.
-
Robust self-navigated body MRI using dense coil arrays.Magn Reson Med. 2016 Jul;76(1):197-205. doi: 10.1002/mrm.25858. Epub 2015 Jul 29. Magn Reson Med. 2016. PMID: 26220204 Free PMC article.
-
Nuclear magnetic resonance imaging of the heart.Cardiovasc Intervent Radiol. 1986;8(5-6):314-20. doi: 10.1007/BF02552368. Cardiovasc Intervent Radiol. 1986. PMID: 3084096
-
Image-guided optimization of the ECG trace in cardiac MRI.Int J Cardiovasc Imaging. 2012 Mar;28(3):587-93. doi: 10.1007/s10554-011-9865-7. Epub 2011 Apr 16. Int J Cardiovasc Imaging. 2012. PMID: 21494770
-
Non-invasive Assessment of Liver Fat in ob/ob Mice Using Ultrasound-Induced Thermal Strain Imaging and Its Correlation with Hepatic Triglyceride Content.Ultrasound Med Biol. 2021 Apr;47(4):1067-1076. doi: 10.1016/j.ultrasmedbio.2020.12.014. Epub 2021 Jan 16. Ultrasound Med Biol. 2021. PMID: 33468357 Free PMC article.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources