Positively charged filters for virus recovery from wastewater treatment plant effluents
- PMID: 6274257
- PMCID: PMC244129
- DOI: 10.1128/aem.42.5.921-924.1981
Positively charged filters for virus recovery from wastewater treatment plant effluents
Abstract
Positively charged Zeta Plus filters were used to concentrate enteroviruses from 19 liters of effluent from activated sludge units. Neither the addition of salts nor the acidification of the effluent was required for adsorption of viruses to the filters. Viruses adsorbed to the filters were eluted by treating the filters with a solution of 4 M urea buffered at pH 9 with 0.05 M lysine. Eluted viruses were concentrated into final volumes of 1 to 2 ml by using a two-step concentration procedure that employed inorganic and organic flocculation. Approximately 50% of the viruses added to effluents could be recovered in the final sample. The procedure was used to monitor effluents from activated sludge units at two wastewater treatment plants for the presence of enteroviruses.
Similar articles
-
Modified membrane-filter procedure for concentration of enteroviruses from tap water.Appl Environ Microbiol. 1985 Feb;49(2):453-5. doi: 10.1128/aem.49.2.453-455.1985. Appl Environ Microbiol. 1985. PMID: 2984992 Free PMC article.
-
Urea-lysine method for recovery of enteroviruses from sludge.Appl Environ Microbiol. 1981 Feb;41(2):455-8. doi: 10.1128/aem.41.2.455-458.1981. Appl Environ Microbiol. 1981. PMID: 6263183 Free PMC article.
-
Evaluation of MK filters for recovery of enteroviruses from tap water.Appl Environ Microbiol. 1994 Jun;60(6):1974-7. doi: 10.1128/aem.60.6.1974-1977.1994. Appl Environ Microbiol. 1994. PMID: 8031090 Free PMC article.
-
Concentration and recovery of viruses from water: a comprehensive review.Food Environ Virol. 2012 Jun;4(2):41-67. doi: 10.1007/s12560-012-9080-2. Epub 2012 May 31. Food Environ Virol. 2012. PMID: 23412811 Review.
-
Upflow anaerobic sludge blanket reactor--a review.Indian J Environ Health. 2001 Apr;43(2):1-82. Indian J Environ Health. 2001. PMID: 12397675 Review.
Cited by
-
Impact of chemical and structural anisotropy on the electrophoretic mobility of spherical soft multilayer particles: the case of bacteriophage MS2.Biophys J. 2008 Apr 15;94(8):3293-312. doi: 10.1529/biophysj.107.115477. Epub 2008 Jan 11. Biophys J. 2008. PMID: 18192368 Free PMC article.
-
Development and application of new positively charged filters for recovery of bacteriophages from water.Appl Environ Microbiol. 1991 Apr;57(4):1218-22. doi: 10.1128/aem.57.4.1218-1222.1991. Appl Environ Microbiol. 1991. PMID: 2059044 Free PMC article.
-
Cellulose-based virus-retentive filters: a review.Rev Environ Sci Biotechnol. 2017;16(3):455-489. doi: 10.1007/s11157-017-9434-1. Epub 2017 Jun 1. Rev Environ Sci Biotechnol. 2017. PMID: 32214924 Free PMC article. Review.
-
Rapid ultrafiltration concentration and biosensor detection of enterococci from large volumes of Florida recreational water.Appl Environ Microbiol. 2008 Aug;74(15):4792-8. doi: 10.1128/AEM.00052-08. Epub 2008 May 30. Appl Environ Microbiol. 2008. PMID: 18515479 Free PMC article.
-
Comparison of microporous filters for concentration of viruses from wastewater.Appl Environ Microbiol. 1984 May;47(5):989-92. doi: 10.1128/aem.47.5.989-992.1984. Appl Environ Microbiol. 1984. PMID: 6742838 Free PMC article.
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources