Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1982 Mar;15(3):353-61.
doi: 10.1128/jcm.15.3.353-361.1982.

Detection of Japanese encephalitis virus immunoglobulin M antibodies in serum by antibody capture radioimmunoassay

Detection of Japanese encephalitis virus immunoglobulin M antibodies in serum by antibody capture radioimmunoassay

D S Burke et al. J Clin Microbiol. 1982 Mar.

Abstract

An assay for detecting human immunoglobulin M (IgM) antibodies to Japanese encephalitis (JE) virus was developed by using the antibody capture solid-phase radioimmunoassay approach (JE IgM ACRIAAA). Heavy-chain-specific goat antihuman IgM was first bound to the wells of a polyvinyl microtiter plate, and successive steps involved sequential binding of test sample IgM, acetone-extracted mouse brain JE antigen, and (125)I-labeled flavivirus hyperimmune human IgG. Among 20 patients hospitalized in Bangkok with clinical diagnoses of acute encephalitis, and with acute flavivirus infections proven by hemagglutination inhibition (HAI) serology, 16 had detectable (positive/negative [P/N] ratio, greater than 3.0) JE IgM ACRIA antibodies in the acute-phase serum specimen, and 19 had such antibodies in the convalescent-phase serum specimen. Convalescent patient sera regularly had higher P/N values than the corresponding acute-phase sera (mean +/- 1 standard deviation = 13.0 +/- 9.3 with acute-phase sera and 25.8 +/- 19.6 with convalescent-phase sera). JE virus-infected patients with HAI serological responses indicative of a primary flavivirus infection had higher JE IgM ACRI P/N responses than did those patients whose serological response indicated past exposure to other flaviviruses. None of 70 serum specimens from healthy Thai adults and children with serum JE HAI antibodies had detectable JE IgM ACRIA activity (P/N ratios all less than or equal to 3.0). Biological false-positives with low P/N ratios (range, 3 to 15) were found in sera from patients with acute or recent infections with flaviviruses other than JE virus but could be differentiated by the fact that these sera gave higher P/N ratios with homologous antigens than with JE virus. False-positive reactions with low P/N ratios (range, 3 to 6) due to serum rheumatoid factor activity were differentiated by testing with control antigen. The JE IgM ACRIA technique permits a rapid, accurate diagnosis of acute JE virus infections in both patients with and those without previous exposure to other flaviviruses.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Am J Epidemiol. 1973 Jul;98(1):29-38 - PubMed
    1. Am J Trop Med Hyg. 1977 May;26(3):533-7 - PubMed
    1. Am J Trop Med Hyg. 1958 Nov;7(6):585-94 - PubMed
    1. J Immunol Methods. 1975 Sep;8(3):223-34 - PubMed
    1. Nature. 1962 May 5;194:495-6 - PubMed

MeSH terms

LinkOut - more resources