A computer system for real-time data acquisition and analysis of biopotentials and quantal content at the neuromuscular junction
- PMID: 6311482
- DOI: 10.1016/0010-468x(83)90078-8
A computer system for real-time data acquisition and analysis of biopotentials and quantal content at the neuromuscular junction
Abstract
A computerized data acquisition system for on-line analysis of the parameters of neuromuscular transmission is described. Both hardware usage and software methodologies are discussed with regard to sampling in real-time and analyzing miniature end-plate potentials (MEPPs), end-plate potentials (EPPs) and quantal content of the evoked transmitter release. Significant features of the program include: (1) automatic threshold determination for MEPP detection; (2) the use of a circular buffer to give pre-trigger information; (3) real-time noise spike rejection; (4) an automatic procedure for EPP failure detection; (5) rapid quantal content determinations by several methods as well as complete MEPP and EPP waveform analysis. The system has proven both accurate and reliable during more than two years of use. Advantages of the system over conventional methods include: (1) increased accuracy and efficiency in data analysis; (2) immediate availability of results; (3) conventional data storage; (4) flexibility to meet changing requirements.