Two-dimensional filtering of SPECT images using the Metz and Wiener filters
- PMID: 6333497
Two-dimensional filtering of SPECT images using the Metz and Wiener filters
Abstract
Two-dimensional filtering, both before and after reconstruction, has been applied to the processing of single photon emission computerized tomographic (SPECT) images. The filters investigated were the count-dependent Metz filter and Wiener filter, both of which automatically adapt to the image being processed. Using a SPECT phantom, with images reconstructed with these filters rather than the ramp, we observed a statistically significant increase (p less than 0.05) in the image contrast for solid Plexiglas spheres, and significant decrease (p less than 0.05) in the percent fractional standard deviation of counts in a region of uniform activity. The adaptability of these filters is demonstrated by a comparison of SPECT acquisitions of the phantom at two different count levels. An example of their application to clinical studies is presented. We conclude that two-dimensional digital image restoration with these techniques can produce a significant increase in SPECT image quality, with a small cost in processing time when these techniques are implemented on an array processor.
Similar articles
-
Digital restoration of indium-111 and iodine-123 SPECT images with optimized Metz filters.J Nucl Med. 1986 Aug;27(8):1327-36. J Nucl Med. 1986. PMID: 3488378
-
Variation of the count-dependent Metz filter with imaging system modulation transfer function.Med Phys. 1986 Mar-Apr;13(2):139-49. doi: 10.1118/1.595938. Med Phys. 1986. PMID: 3486341
-
An image-dependent Metz filter for nuclear medicine images.J Nucl Med. 1988 Dec;29(12):1980-9. J Nucl Med. 1988. PMID: 3264021
-
Image filtering in single-photon emission computed tomography: principles and applications.Comput Med Imaging Graph. 2001 Mar-Apr;25(2):127-33. doi: 10.1016/s0895-6111(00)00063-x. Comput Med Imaging Graph. 2001. PMID: 11137789 Review.
-
Filters in 2D and 3D Cardiac SPECT Image Processing.Cardiol Res Pract. 2014;2014:963264. doi: 10.1155/2014/963264. Epub 2014 Apr 1. Cardiol Res Pract. 2014. PMID: 24804144 Free PMC article. Review.
Cited by
-
Quantitative analysis in single photon emission tomography (SPET).Eur J Nucl Med. 1992;19(1):47-61. doi: 10.1007/BF00178308. Eur J Nucl Med. 1992. PMID: 1547808 Review.
-
Optimization of Butterworth filter for brain SPECT imaging.Ann Nucl Med. 1993 May;7(2):71-7. doi: 10.1007/BF03164571. Ann Nucl Med. 1993. PMID: 8318350
-
Singular value decomposition for photon-processing nuclear imaging systems and applications for reconstruction and computing null functions.Phys Med Biol. 2015 Sep 21;60(18):7359-85. doi: 10.1088/0031-9155/60/18/7359. Epub 2015 Sep 9. Phys Med Biol. 2015. PMID: 26350439 Free PMC article.
-
High-resolution versus high-sensitivity SPECT imaging with geometric blurring compensation for various parallel-hole collimation geometries.IEEE Trans Inf Technol Biomed. 2010 Jul;14(4):1121-7. doi: 10.1109/TITB.2010.2050145. Epub 2010 May 10. IEEE Trans Inf Technol Biomed. 2010. PMID: 20460211 Free PMC article.
-
Optimal preprocessing Butterworth-Wiener filter for Tl-201 myocardial SPECT.Eur J Nucl Med. 1987;13(8):404-7. doi: 10.1007/BF00292492. Eur J Nucl Med. 1987. PMID: 3501758
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources