A new headholder for PET, CT, and NMR imaging
Abstract
A new headholder was developed for patient restraint and repositioning during positron emission tomography (PET), CT, and nuclear magnetic resonance (NMR) imaging procedures. A customized form was produced for each patient by pouring polyurethane resin and catalyst between an injection-molded polystyrene shell and a protective latex sheet and placing the patient's head in the form while the resin set. Excellent head restraint and repositioning was achieved when the headholder was used with a crossed-laser system. Repositioning accuracy was demonstrated by comparing transmission scans of the same patient obtained on different days and by comparing PET transmission scans with coplanar CT scans. No artifacts due to the headholder were apparent in CT, PET, and NMR images.
Similar articles
-
[A new headholder for positron emission tomography].Kaku Igaku. 1993 Oct;30(10):1241-4. Kaku Igaku. 1993. PMID: 8264115 Japanese.
-
Head holder for PET, CT, and MR studies.J Comput Assist Tomogr. 1991 Sep-Oct;15(5):886-92. doi: 10.1097/00004728-199109000-00034. J Comput Assist Tomogr. 1991. PMID: 1885820
-
Anatomical localization schemes for use in positron computed tomography using a specially designed headholder.J Comput Assist Tomogr. 1982 Aug;6(4):848-53. doi: 10.1097/00004728-198208000-00043. J Comput Assist Tomogr. 1982. PMID: 6981660
-
X-ray-based attenuation correction for positron emission tomography/computed tomography scanners.Semin Nucl Med. 2003 Jul;33(3):166-79. doi: 10.1053/snuc.2003.127307. Semin Nucl Med. 2003. PMID: 12931319 Review.
-
Positron emission tomography/computed tomography.Semin Nucl Med. 2008 May;38(3):152-66. doi: 10.1053/j.semnuclmed.2008.01.003. Semin Nucl Med. 2008. PMID: 18396176 Review.
Cited by
-
Effects of central cholinergic blockade on striatal dopamine release measured with positron emission tomography in normal human subjects.Proc Natl Acad Sci U S A. 1993 Dec 15;90(24):11816-20. doi: 10.1073/pnas.90.24.11816. Proc Natl Acad Sci U S A. 1993. PMID: 8265632 Free PMC article.
-
Quantification of fMRI artifact reduction by a novel plaster cast head holder.Hum Brain Mapp. 2000 Nov;11(3):207-13. doi: 10.1002/1097-0193(200011)11:3<207::aid-hbm60>3.0.co;2-j. Hum Brain Mapp. 2000. PMID: 11098798 Free PMC article.
-
Applying independent component analysis to clinical FMRI at 7 t.Front Hum Neurosci. 2013 Sep 2;7:496. doi: 10.3389/fnhum.2013.00496. eCollection 2013. Front Hum Neurosci. 2013. PMID: 24032007 Free PMC article.
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Medical