Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1983 Mar-Apr:6 Suppl 1:29-34.

Comparison of porcine insulin and human insulin (Novo) using the glucose-controlled insulin infusion system, glucose-insulin dose-response curves, and the outpatient effectiveness of human insulin (Novo) in insulin-dependent diabetes

  • PMID: 6343034
Comparative Study

Comparison of porcine insulin and human insulin (Novo) using the glucose-controlled insulin infusion system, glucose-insulin dose-response curves, and the outpatient effectiveness of human insulin (Novo) in insulin-dependent diabetes

M A Charles et al. Diabetes Care. 1983 Mar-Apr.

Abstract

The usefulness of human insulin (Novo) in the treatment of diabetes was studied in eight insulin-dependent diabetic patients. Evaluation was carried out through three methods: (1) glucose-controlled insulin infusion system on two separate days during the patients' ingestion of mixed meals; (2) euglycemic clamp method; and (3) evaluation of patients for 3 mo using short- and intermediate-acting insulins. Employing the glucose-controlled insulin infusion system resulted in mean daily insulin requirements of 84 +/- 9 U and 85 +/- 6 U SEM for porcine and human insulin, respectively (P = NS). Plasma glucose levels attained during the euglycemic clamp were 96 +/- 3 mg/dl. At each insulin infusion rate, the steady-state glucose infusion rates for porcine insulin were 1.12 +/- 0.22, 1.90 +/- 0.58, 4.28 +/- 0.61, and 9.37 +/- 0.66 mg/kg/min compared with 1.27 +/- 0.42, 2.38 +/- 0.20, 4.25 +/- 0.43, and 8.87 +/- 0.67 mg/kg/min for human insulin. No complications of either insulin preparation were observed in the 3-mo patient evaluation. Human insulin was associated with lower levels of circulating insulin antibody (P less than 0.03). In addition, hemoglobin A1c levels decreased from 8.4 to 6.9% (P less than 0.035), and normal hemoglobin A1c levels were maintained in patients using portable insulin infusion pumps.

PubMed Disclaimer

Publication types

LinkOut - more resources