Microbial investigation of the air in an apartment building
- PMID: 6358346
- PMCID: PMC2129367
- DOI: 10.1017/s0022172400060290
Microbial investigation of the air in an apartment building
Abstract
The microbial and viral flora in the ventilating ducts of an apartment building was evaluated. Several types of sampler (slit sampler, Andersen sampler, large volume air sampler) were used to evaluate the hourly, weekly and seasonal variation of this flora. The mean bacterial concentration was 17.2 e.f.u./m3 with a maximum level at 07.30 h (41.3 c.f.u./m3) and a minimal concentration in the early afternoon (8 c.f.u./m3). The bacterial concentration observed correlated with the relative humidity in the air-ducts although there were no seasonal differences. The bacteria were mainly gram-positive cocci (73.5%) represented by a large number of Micrococcaceae (47.1%); gram-positive bacilli accounted for 14.2% of the isolates, gram-negative bacilli 12.0% and gram-negative cocci 0.3%. The majority of the bacteria-carrying particles were in the respirable range with 80.4% of them being less than 5 microns. The methods used did not result in the isolation of viruses during the winter sampling period.
Similar articles
-
Concentrations of airborne culturable bacteria in 100 large US office buildings from the BASE study.Indoor Air. 2005;15 Suppl 9:71-81. doi: 10.1111/j.1600-0668.2005.00346.x. Indoor Air. 2005. PMID: 15910532
-
Variability of airborne microflora in a hospital ward within a period of one year.Ann Agric Environ Med. 2006;13(1):99-106. Ann Agric Environ Med. 2006. PMID: 16841880
-
Bioaerosol emissions from a suburban yard waste composting facility.Ann Agric Environ Med. 2001;8(2):177-85. Ann Agric Environ Med. 2001. PMID: 11748875
-
[Burden of fattening pigs and the environment of the pig fattening farms caused by lung-passing dust particles, pig stall specific bacteria and ammonia].Zentralbl Hyg Umweltmed. 1995 Jan;196(5):399-415. Zentralbl Hyg Umweltmed. 1995. PMID: 7727021 German.
-
Use of mass spectrometry for characterising microbial communities in bioaerosols.Ann Agric Environ Med. 2001;8(2):111-7. Ann Agric Environ Med. 2001. PMID: 11748866 Review.
Cited by
-
Culturable airborne bacteria in outdoor environments in Beijing,China.Microb Ecol. 2007 Oct;54(3):487-96. doi: 10.1007/s00248-007-9216-3. Epub 2007 Feb 17. Microb Ecol. 2007. PMID: 17308950
-
Indoor climate and air quality in new offices: effects of a reduced air-exchange rate.Int Arch Occup Environ Health. 1991;63(4):233-9. doi: 10.1007/BF00386371. Int Arch Occup Environ Health. 1991. PMID: 1743764
-
Longitudinal study of dust and airborne endotoxin in the home.Environ Health Perspect. 2000 Nov;108(11):1023-8. doi: 10.1289/ehp.001081023. Environ Health Perspect. 2000. PMID: 11102291 Free PMC article.
References
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources