'Y' connector system for prevention of peritonitis in CAPD: a controlled study
- PMID: 6361737
'Y' connector system for prevention of peritonitis in CAPD: a controlled study
Abstract
To compare the efficacy of the standard Oreopoulos CAPD system with that of a new method consisting of a Y-shaped set filled with sodium hypochlorite during the dwelling time, a randomised controlled study was performed in 62 new CAPD patients. Life table analysis showed a significantly (p less than 0.001) less frequent incidence of peritonitis in the group treated with the Y connector system. This study shows that the Y system appears to be effective in reducing the incidence of peritonitis, as compared with the standard technique, in patients on the CAPD programme. The method is simple and economical and the incidence and the severity of side effects appear to be acceptable.
Similar articles
-
Prospective controlled trial of a Y-connector and disinfectant to prevent peritonitis in continuous ambulatory peritoneal dialysis.Lancet. 1983 Sep 17;2(8351):642-4. doi: 10.1016/s0140-6736(83)92528-x. Lancet. 1983. PMID: 6136794 Clinical Trial.
-
'O' set connector system in CAPD.J Assoc Physicians India. 1996 Sep;44(9):602-5. J Assoc Physicians India. 1996. PMID: 9251369
-
A prospective, randomized study comparing the peritonitis incidence of CAPD and Y-connector (CAPD-Y) with continuous cyclic peritoneal dialysis (CCPD).Adv Perit Dial. 1991;7:186-9. Adv Perit Dial. 1991. PMID: 1680422 Clinical Trial.
-
Do the Y-set and double-bag systems reduce the incidence of CAPD peritonitis? A systematic review of randomized controlled trials.Nephrol Dial Transplant. 2001 Feb;16(2):341-7. doi: 10.1093/ndt/16.2.341. Nephrol Dial Transplant. 2001. PMID: 11158410
-
[Prevention of peritonitis in continuous ambulatory peritoneal dialysis].Nephrologie. 1989;10 Suppl:46-9. Nephrologie. 1989. PMID: 2510034 Review. French.
Cited by
-
Antimicrobial agents for preventing peritonitis in peritoneal dialysis patients.Cochrane Database Syst Rev. 2017 Apr 8;4(4):CD004679. doi: 10.1002/14651858.CD004679.pub3. Cochrane Database Syst Rev. 2017. PMID: 28390069 Free PMC article.
-
Double bag or Y-set versus standard transfer systems for continuous ambulatory peritoneal dialysis in end-stage kidney disease.Cochrane Database Syst Rev. 2014 Aug 13;2014(8):CD003078. doi: 10.1002/14651858.CD003078.pub2. Cochrane Database Syst Rev. 2014. PMID: 25117423 Free PMC article.