Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1983 Dec;135(2):423-30.
doi: 10.1016/0003-2697(83)90705-4.

Detection of enzymatic activities in sodium dodecyl sulfate-polyacrylamide gels: DNA polymerases as model enzymes

Detection of enzymatic activities in sodium dodecyl sulfate-polyacrylamide gels: DNA polymerases as model enzymes

A Blank et al. Anal Biochem. 1983 Dec.

Abstract

Recent techniques for detecting the catalytic activity of enzymes in sodium dodecyl sulfate (SDS)-polyacrylamide gels have been hampered by lack of reproducibility associated with variability in commercial SDS preparations. Simple expedients which facilitate reproducible detection of DNA polymerase activity and which appear to be widely applicable to detection of other enzymes are reported here. It was observed that reproducibility of a reported procedure for DNA polymerase detection (Spanos, A., Sedgwick, S. G., Yarranton, G. T., Hübscher, U., and Banks, G. R. (1981) Nucl. Acids Res. 9, 1825-1839) depends on the SDS used for electrophoresis, and that sensitivity is markedly reduced if currently available SDS is substituted for the discontinued product specified by Spanos et al. A modified procedure yielding sensitivity with contemporary commercial SDS, which exceeds the sensitivity observed when using the protocol and the SDS originally specified, is described. The modifications employed, which presumably promote renaturation of enzymes, are (1) embedding fibrinogen in gels and (2) washing detergent from gels with aqueous isopropanol after electrophoresis. These expedients permit detection of picogram amounts of Escherichia coli DNA polymerase 1 and its Klenow fragment and nanogram amounts of calf thymus alpha and rat liver (Novikoff hepatoma) beta polymerases. Finally, it is shown that sensitivity of DNA polymerase detection is reduced by lipophilic contaminants in contemporary commercial SDS, and that the expedients employed here mitigate the deleterious effect of these impurities.

PubMed Disclaimer

Publication types

LinkOut - more resources